Connector P/N 277909
E 2014 Nordson Corporation
See Figure 3‐9.
2. Connect each pair of input wires to the appropriate terminals (8 through
14) on connector P/N 277909. If input number four is used, terminal 7 on
connector P/N 277908 must also be used. Both connectors are provided
in the installation kit. Table 3‐8 lists the terminal numbers that correspond
to each input.
NOTE: Connector P/N 277909 is physically keyed to prevent it from
being used in place of connector P/N 277908, which has terminals
numbered 1 through 7.
3. Plug the connector (P/N 277909) into the bottom receptacle of terminal
TB2, which is located on the right side of the main board. If input number
four is used, plug connector P/N 277908 into the top receptacle on
terminal TB2.
Figure 3‐9
Wiring inputs
TB2
8
9 10 11 12 13 14
3-41