Nordson ProBlue P4 Customer Product Manual page 76

Adhesive melters
Table of Contents

Advertisement

3-46
Installation
Installing Melter Outputs
Output
Terminals
Standard Outputs
1
1 and 2
2
3 and 4
3
5 and 6
Optional Outputs
4
1 and 2
5
3 and 4
6
5 and 6
7
7 and 8
NOTE
A:
When control option condition occurs, contacts close. Contacts are normally open when power is off.
B:
When control option condition occurs, contacts open. Contacts are normally open when power is off.
C:
Control option 6 provides an output signal when a potential fault is detected. If control option 3 and 6 are both used,
then both a fault output and an alert output signal will be present when the fault LED turns on.
D:
For wiring information, refer to the instruction sheet that is provided with the optional I/O expansion card
Part 1024496_06
Table 3‐9 Output Data
Operating
Parameter
40
0 ‐ Output Disabled
1 ‐ Ready (Default)
2 ‐ Ready and the pump is on
3 ‐ Fault
4 ‐ Tank Low Level
5 ‐ Service LED is On
6 ‐ Alert
41
Same as parameter 40 (Default=3)
42
Same as parameter 40 (Default=4)
43
0 (Disabled)
44
0 (Disabled)
45
0 (Disabled)
46
0 (Disabled)
(contd)
Control Options
Note
A
A
A
B
A
C
D