Online Commands; Overview Of Commands And Parameters - Leuze electronic BCL 8 Series Original Operating Instructions

Bar code reader with integrated decoder
Hide thumbs Also See for BCL 8 Series:
Table of Contents

Advertisement

Online commands

11
Online commands
11.1

Overview of commands and parameters

Online commands can be used to send commands directly to the device for control and
configuration. For this, the BCL 8 has to be connected to computer (host) via the serial inter-
face.
For information on the transmission protocol, please see Chapter 7.3.2.
Using the online commands you can:
• control/decode the reading gate.
• read/write/copy parameters.
• carry out an automatic configuration.
• teach/set a reference code.
• call up error messages.
• call up statistical device information.
• carry out a software reset in order to reinitialize the device.
Syntax
Online commands consist of one or two ASCII characters followed by command parame-
ters.
No separation characters may be entered between the command and the command param-
eter(s). Both small and capitalized letters can be used.
Example:
Command 'CA':
Parameter '+':
Transmitted is:
Notation
Commands, command parameters and returned data are enclosed between single quota-
tion marks ' ' in the text of this manual.
Most online commands are acknowledged by the BCL 8 and any requested data returned.
For commands that are not acknowledged, command execution can be observed or moni-
tored directly on the device.
58
autoConfig function
Activation
'CA+'
BCL 8
Leuze electronic

Advertisement

Table of Contents
loading

Table of Contents