Communicating with the Device
9.2

Overview of Commands and Parameters

Online commands can be used to send commands directly to the device for control and
configuration.
For this, the BPS 37 has to be connected to a host or service computer via the serial inter-
face. The commands can be sent either via the host or the service interface.
9.2.1

General 'Online' Commands

Command
M+
M-
MI
MNx=yzzzzzzz
MNR
MMxyyyy
MM-
PC20
32
Activating the measurement
Deactivating the measurement
Reversing the count direction
With the standard setting, the calculation is performed back from the max.
measurement length (10000 metre)
Set pre-set value
x = T = value is stored temporarily
(the value is erased after switching on and off)
x = D = value is stored permanently in the EPROM
y = sign for pre-set value
zzzzzzz = specification of the pre-set value in mm
Example: MND=+0001000
Current position is set permanently to +1000 mm.
Deactivates the pre-set value. The unformatted measurement value is
output.
Controls the data output via the service interface
x = S = a measurement value is output (Single Shot Mode); subsequent
specification of the time not necessary
x = T = measurement values are output cyclically; time must be subse-
quently specified
y = time specification in ms
Example: MMT0500
Measurement values are output via the service interface in a time interval
of 500ms
Deactivating the function MMTyyyy
If the cyclical output via the service interface is no longer required, the
function must be deactivated using the command MM.
Resetting all parameters in the BPS 37 to Leuze default values.
Version query
Description
BPS 37
Leuze
electronic
Leuze electronic