Snmp-Server View; Table 4-42 Show Snmp Engine-Id - Display Description - SMC Networks SMC TigerStack III SMC6824M Management Manual

24-port fast ethernet switch
Hide thumbs Also See for SMC TigerStack III SMC6824M:
Table of Contents

Advertisement

SNMP C
OMMANDS
Field
Local SNMP
engineID
Local SNMP
engineBoots
Remote SNMP
engineID
IP address

snmp-server view

This command adds an SNMP view which controls user access to the MIB.
Use the no form to remove an SNMP view.
Syntax
snmp-server view view-name oid-tree {included | excluded}
no snmp-server view view-name
• view-name - Name of an SNMP view. (Range: 1-64 characters)
• oid-tree - Object identifier of a branch within the MIB tree. Wild cards
can be used to mask a specific portion of the OID string. (Refer to the
examples.)
• included - Defines an included view.
• excluded - Defines an excluded view.
Default Setting
defaultview (includes access to the entire MIB tree)
Command Mode
Global Configuration
Command Usage
• Views are used in the snmp-server group command to restrict user
access to specified portions of the MIB tree.
• The predefined view "defaultview" includes access to the entire MIB
tree.
4-162

Table 4-42 show snmp engine-id - display description

Description
String identifying the local engine ID.
The number of times that the engine has (re-)initialized since
the snmp EngineID was last configured.
String identifying an engine ID on a remote device.
IP address of the device containing the corresponding remote
SNMP engine.

Hide quick links:

Advertisement

Table of Contents
loading