Power Inline Priority - SMC Networks SMC TigerStack III SMC6824M Management Manual

24-port fast ethernet switch
Hide thumbs Also See for SMC TigerStack III SMC6824M:
Table of Contents

Advertisement

P
E
OWER OVER
Command Mode
Interface Configuration
Command Usage
If a device is connected to a switch port and the switch detects that it
requires more than the maximum power allocated to the port, no power
is supplied to the device (i.e., port power remains off).
Example
Console(config)#interface ethernet 1/1
Console(config-if)#power inline maximum allocation 8000
Console(config-if)#

power inline priority

This command sets the power priority for specific ports. Use the no form to
restore the default setting.
Syntax
power inline priority priority
no power inline priority
priority - The power priority for the port.
Options: 1 (critical), 2 (high), or 3 (low)
Default Setting
3 (low)
Command Mode
Interface Configuration
Command Usage
• If the power demand from devices connected to the switch exceeds the
power budget setting, the switch uses port power priority settings to
control the supplied power. For example:
- A device connected to a low-priority port that causes the switch to
exceed its budget is not supplied power.
- A device connected to a critical or high-priority port that causes the
switch to exceed its budget is supplied power, but the switch drops
power to one or more lower-priority ports.
4-94