CLI – This example shows statistics for port 13.
Console#show interfaces counters ethernet 1/13
Ethernet 1/13
Iftable stats:
Octets input: 868453, Octets output: 3492122
Unicast input: 7315, Unitcast output: 6658
Discard input: 0, Discard output: 0
Error input: 0, Error output: 0
Unknown protos input: 0, QLen output: 0
Extended iftable stats:
Multi-cast input: 0, Multi-cast output: 17027
Broadcast input: 231, Broadcast output: 7
Ether-like stats:
Alignment errors: 0, FCS errors: 0
Single Collision frames: 0, Multiple collision frames: 0
SQE Test errors: 0, Deferred transmissions: 0
Late collisions: 0, Excessive collisions: 0
Internal mac transmit errors: 0, Internal mac receive errors: 0
Frame too longs: 0, Carrier sense errors: 0
Symbol errors: 0
RMON stats:
Drop events: 0, Octets: 4422579, Packets: 31552
Broadcast pkts: 238, Multi-cast pkts: 17033
Undersize pkts: 0, Oversize pkts: 0
Fragments: 0, Jabbers: 0
CRC align errors: 0, Collisions: 0
Packet size <= 64 octets: 25568, Packet size 65 to 127 octets: 1616
Packet size 128 to 255 octets: 1249, Packet size 256 to 511 octets: 1449
Packet size 512 to 1023 octets: 802, Packet size 1024 to 1518 octets: 871

Power Over Ethernet Settings

The SMC6824MPE and SMC6826MPE can provide DC power to a wide
range of connected devices, eliminating the need for an additional power
source and cutting down on the amount of cables attached to each device.
Once configured to supply power, an automatic detection process is
initialized by the switch that is authenticated by a PoE signature from the
connected device. Detection and authentication prevent damage to
non-802.3af compliant devices.
The switch's power management enables total switch power and individual
port power to be controlled within a configured power budget. Port power
can be automatically turned on and off for connected devices, and a
per-port power priority can be set so that the switch never exceeds its
allocated power budget. When a device is connected to a switch port, its
power requirements are detected by the switch before power is supplied. If