Figure 75: Stripping The Power Wires; Figure 76: Attaching The Power Wires To The Straight Terminal Lugs - Allied Telesis AT-SB*908 GEN2 Installation Manual

Advanced layer 3 plus modular switch, alliedware plus v5.4.8-0, virtual chassis stacking, chassis, ethernet line card, fan module, ac/dc power supply
Table of Contents

Advertisement

Chapter 5: Powering On the Chassis
120
Figure 75. Stripping the Power Wires
Note
You must use stranded wires with the terminal lugs. You may not
use solid wires.
2. Insert the power wires into the terminals included with the power
supply and use a crimping tool to secure the wires to the terminals.
See Figure 76.
Figure 76. Attaching the Power Wires to the Straight Terminal Lugs
3. Verify that the On/Off switch on AT-SBxPWRSYS1-80 Power Supply
is in the Off position. Refer to Figure 67 on page 113.
4. Use a #1 Phillips-head screwdriver to loosen the two screws on the
plastic cover over the positive and negative terminals on the power
supply and slide the cover to the right, as shown in Figure 77 on page
121. You may need to lift the locking handle slightly to access the
bottom screw.