Allied Telesis AT-SB*908 GEN2 Installation Manual page 143

Advanced layer 3 plus modular switch, alliedware plus v5.4.8-0, virtual chassis stacking, chassis, ethernet line card, fan module, ac/dc power supply
Table of Contents

Advertisement

Table 12. Switch Configuration Procedures (Continued)
Step
4
Write down the feature
licenses.
5
Enable the VCStack
feature.
6
Save your changes
7
Reboot the switch.
8
Wait three minutes for the
switch to initialize its
operating software.
9
Start a new local
management session.
10
Designate the trunk ports
for the switch.
11
Save your changes
12
Power off the switch.
13
Repeat steps 1 to 12 on
each switch.
14
Compare the version
numbers of the
AlliedWare Plus operating
software on the switches.
If necessary, upgrade the
switches so that they all
have the same version.
15
Compare the optional
feature licenses. If
necessary, add or remove
licenses so that they all
have the same licenses.
Description
"Viewing Optional Feature
Licenses" on page 150
"Enabling the VCStack
Feature" on page 151
-
"Starting a Local
Management Session" on
page 145
"Designating Trunk Ports"
on page 153
"Powering Off the Switch"
on page 156
-
-
-
AT-SBx908 GEN2 Installation Guide for Virtual Chassis Stacking
Procedure
SHOW LICENSE BRIEF
command in User Exec or
Privileged Exec mode.
STACK ENABLE
command in the Global
Configuration mode.
WRITE command in the
Privileged Exec mode.
REBOOT command in the
Privileged Exec mode.
-
-
STACKPORT command
in port Interface modes.
WRITE command in the
Privileged Exec mode.
-
-
Software Reference for
SBx908 GEN2 Series
Switches, AlliedWare
Plus Operating System
Software Reference for
SBx908 GEN2 Series
Switches, AlliedWare
Plus Operating System
AlliedWare Plus
Command or Manual
143

Advertisement

Table of Contents
loading

Table of Contents