Chapter 5: Powering On the Switch
82
Figure 40. Loosening the Captive Screws on the DC Connector
4. Remove 6.5mm (0.25 in.) of insulation from one end of the black
RETURN wire. Refer to Figure 41.
Figure 41. Stripping a Stranded Power Wire
5. Insert the black RETURN wire into the right connector and secure it by
tightening the captive screw with a flat-head screwdriver. Allied Telesis
recommends tightening the screw to 5 in-lbs. Refer to Figure 42.
Figure 42. Inserting the RETURN Wire
6.5 mm
(0.25 in.)