Enabling The Vcstack Feature; Table 13: Commands For Enabling The Vcstack Feature - Allied Telesis AT-SB*908 GEN2 Installation Manual

Advanced layer 3 plus modular switch, alliedware plus v5.4.8-0, virtual chassis stacking, chassis, ethernet line card, fan module, ac/dc power supply
Table of Contents

Advertisement

Enabling the VCStack Feature

awplus> enable
awplus#
awplus# configure terminal
Enter configuration commands, one per line. End
with CNTL/Z.
awplus(config)#
awplus(config)# stack enable
% The device needs to be restarted for this change
to take effect.
awplus(config)#
awplus(config)# exit
awplus#
The default setting for the VCStack feature is disabled. The following
procedure explains how to enable it.
Note
This procedure requires reseting the switch. Some network traffic
will be lost if the switch is connected to an active network.
To enable the stacking feature, perform the procedure in Table 13.
Table 13. Commands for Enabling the VCStack Feature
Command
AT-SBx908 GEN2 Installation Guide for Virtual Chassis Stacking
Description
Start a local management session
on the switch. For instructions,
refer to "Starting a Local
Management Session" on
page 145.
Enter the ENABLE command to
move from the User Exec mode to
the Privileged Exec mode.
Enter the CONFIGURE
TERMINAL command to move to
the Global Configuration mode.
Enter the STACK ENABLE
command to activate VCStack on
the switch.
Enter the EXIT command to return
to the Privileged Exec mode.
151