Figure 82: Tightening The Handle Locking Screw - Allied Telesis AT-SB*908 GEN2 Installation Manual

Advanced layer 3 plus modular switch, alliedware plus v5.4.8-0, virtual chassis stacking, chassis, ethernet line card, fan module, ac/dc power supply
Table of Contents

Advertisement

Chapter 5: Powering On the Chassis
126
Figure 82. Tightening the Handle Locking Screw
10. Before attaching the power wires from the power supply to the circuit
breaker in the wiring closet, check that the circuit breaker is off.
11. Connect the power wires to the circuit breaker.
12. If you have two AT-SBxPWRSYS1-80 DC Power Supplies for the
switch, repeat this procedure to install the second power supply.
13. Turn the DC circuit breaker(s) on.
14. Turn the On/Off switch(es) on the AT-SBxPWRSYS1-80 DC Power
Supply(ies) to the On position. See Figure 67 on page 113.
15. Do one of the following:
To monitor the switch as it initializes the management software, go
to "Monitoring the Initialization Processes" on page 137.
Wait three minutes for the switch to initialize its management
software. Afterwards, go to Chapter 6, "Configuring Switches for
Stacking" on page 141.
Handle locking
screw