Starting A Local Management Session - Allied Telesis AT-SB*908 GEN2 Installation Manual

Advanced layer 3 plus modular switch, alliedware plus v5.4.8-0, virtual chassis stacking, chassis, ethernet line card, fan module, ac/dc power supply
Table of Contents

Advertisement

Starting a Local Management Session

To start a local management session on the switch, perform the following
procedure. If the switch is powered off, start with step 1. If the switch is
already powered on, start with step 3:
Note
The initial management session has to be a local session because
the AlliedWare Plus operating software does not come with a default
IP address.
1. Power on the switch by doing one of the following:
If the switch has an AC power supply, connect the AC power cord
to the power supply on the back panel and to an AC power source.
if the switch has two power supplies, you need to power on only
one of them for this procedure.
If the switch has the AT-SBxPWRSYS1-80 DC Power Supply,
power on the DC circuit and the On/Off switch on the power supply.
(If you have not yet wired the DC connector on the power supply,
refer to "Powering On AT-SBxPWRSYS1-80 DC Power Supplies"
on page 110.)
2. Wait three minutes for the switch to initialize the management
software.
3. Connect the RJ-45 end of the management card included with the
switch to the Console RS-232 port on the management panel. Refer to
Figure 95.
AT-SBx908 GEN2 Installation Guide for Virtual Chassis Stacking