Figure 42. Stripping a Power Cable Wire
Warning
Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by
leaving exposed wire on the terminal block after installation.  E10
2. Tightly wrap the wire strands with your finger tips. Refer to Figure 36
on page 89.
This step is to prevent loose strands from touching other wires and
causing an electrical short.
Note
Allied Telesis recommends that you also tin the wires with solder as
added protection against loose strands. This guide does not provide
instructions on how to tin wires.
3. Remove the PWR 1 - PWR 2 connector from the top panel. Refer to
Figure 43.
Figure 43. Removing the PWR 1 - PWR 2 Cable Connector
IE300 Series Installation Guide
6.5mm
(0.25 in.)