Allied Telesis AT-SB*908 GEN2 Installation Manual page 204

Advanced layer 3 plus modular switch, alliedware plus v5.4.8-0, virtual chassis stacking, chassis, ethernet line card, fan module, ac/dc power supply
Table of Contents

Advertisement

Chapter 10: Troubleshooting
204
Problem 6: The SHOW STACK command is not displaying all the
switches in the stack.
Solutions: The switches are unable to form the stack. Try the following:
The switch might have an earlier version of the management
software that does not support the stacking feature. Perform
"Viewing the AlliedWare Plus Version Number" on page 149.
Review the information in "Stacking Guidelines" on page 41 to
verify that the trunk complies with all rules and restrictions.
If the trunk is using fiber optic transceivers, verify that they are fully
inserted into the transceiver slots.
Verify that the transceivers are from Allied Telesis.
Verify that the fiber optic cables are securely connected to the
ports on the transceivers.
Verify that VCStack is activated on the switches. For instructions,
refer to "Enabling the VCStack Feature" on page 151.
Problem 7: A line card port that was functioning as a stacking port is not
forwarding regular Ethernet traffic after the stacking function is removed.
You have to reboot the switch after changing a stacking port to a
regular Ethernet port.
Problem 8: The switch functions intermittently.
Solutions: Check the system hardware status through the management
software:
Use the SHOW SYSTEM ENVIRONMENT command in the
Privileged Exec mode to verify that the input voltage from the
power source to the switch is stable and within the approved
operating range. The unit will shut down if the input voltage
fluctuates above or below the approved operating range.
Use the SHOW SYSTEM ENVIRONMENT command in the
Privileged Exec mode to verify that the fan is operating correctly.
Verify that the location of the switch allows for adequate airflow.
The unit will shut down if it is overheating.
Problem 9: The Switch ID LED on the front panel is flashing the letter "F."
Solutions: One or more of the following problems has occurred:
A cooling fan has failed.
The internal temperature of the switch has exceeded the normal
operating range and the switch might have to shut down.
Contact your Allied Telesis sales representative for assistance.

Advertisement

Table of Contents
loading

Table of Contents