Switch Quantity Terminal Parameters - Veichi AC90 Manual

Tension control frequency inverter
Table of Contents

Advertisement

AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
9.3 Quantum digital terminal functions
F2.00
Multifunction input terminal 1(X1)
F2.01
Multifunction input terminal 2(X2)
F2.02
Multifunction input terminal 3(X3)
F2.03
Multifunction input terminal 4(X4)
F2.04
Multifunction input terminal 5(X5)
F2.05
Multifunction input terminal 6(X6)
F2.06
Multifunction input terminal 7(X7)
F2.07
Multifunction input terminal 8(X8)
Multifunction terminal (X1-X8) function can be defined by [F2.00-F2.07]. And trait and filter time can be defined by
[F2.08-F2.11]. Setting and function table:
setting
0
No function( can choose again)
1
FWD
2
REV
3
3 line run control(Xi)
4
FWD JOG
5
REV JOG
6
Free stop
7
Emergency stop
8
Fault reset
9
Out fault input
10
Frequency (UP)
11
Freuqncy (DW)
12
(UP/DW clear )
13
Reserved
14
Reserved
15
Multi steps terminal 1
16
Multi steps terminal 2
17
Multi steps terminal 3
18
Multi steps terminal 4
19
ACC/DEC time selection terminal 1
20
ACC/DEC time selection terminal 2
21
ACC/DEC pause
22
PID control cancel
23
PID control pause
24
PID trait switch
25
PID give switch 1
26
PID give switch 2
27
PID give switch 3
28
PID give switch 1
0: No function This terminal invalid.
1: FWD While run order is given by terminal, and [F2.12] is set as 2 lines 1, and terminal is valid, inverter will FWD.
Other control mode refers to [F2.12].
2: REV While run oder is given by terminal, and [F2.12] is set as 2 lines 1, and terminal is valid, inverter will REV. Other
control mode refers to [F2.12].
3: 3 lines run control (Xi) While run oder is given by terminal, and [F2.12] is set as 3 lines 1/2, it is 3 lines run control
(Xi). Details refer to [F2.12].
4: FWD JOG
setting
Setting range: 0-57
setting
29
PID give switch 2
30
PID give switch 3
31
PLC pause
32
PLC restart
33
Swing frequency in
34
Swing frequency pause
35
Swing frequency seset
36
Frequency channel switch terminal 1
37
Frequency channel switch terminal 2
38
Frequency channel switch terminal 3
39
Frequency channel switch terminal 4
40
Timer touch terminal
41
Timer clear terminal
42
Counter clock input terminal
43
Counter clear terminal
44
DC brake order
45
Pre-excitation order terminal
46
Reserved
47
Start magnetic particle clutch function
48
PID parameter switch terminal 1
49
PID parameter switch terminal 2
50
Initial roll diameter setting terminal 1
51
Initial roll diameter setting terminal 2
52
Linear speed selection terminal
53
Material thickness selection terminal
54
Full roll diameter selection terminal
55
Empty to full roll time selection terminal
56
Roll diameter reset terminal
57
Roll diameter calculation pause
86
Function Parameter specifications
Factory set:1
Factory set:2
Factory set:4
Factory set:5
Factory set:6
Factory set:8
Factory set:56
Factory set:57
setting

Advertisement

Table of Contents
loading

Table of Contents