Veichi AC90 Manual page 117

Tension control frequency inverter
Table of Contents

Advertisement

AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Torque control FWD upper frequency limit No set: It sets FWD speed limit under torque control.
Torque control FWD upper frequency limit bias: It adjusts FWD speed limit. After bias, FWD frequency under torque
control is.
FWD frequency under torque control= Torque control FWD upper frequency limit No set+(max frequency*
Torque control FWD upper frequency limit bias)
Torque control REV upper
F7.26
frequency limit No set
Torque control REV upper
F7.27
frequency limit bias
Torque control REV upper frequency limit No set: It sets REV speed limit under torque control.
Torque control REV upper frequency limit bias: It adjusts REV speed limit. After bias, FWD frequency under torque
control is.
REV frequency under torque control= Torque control REV upper frequency limit No set+(max frequency
Torque control REV upper frequency limit bias)
Upper frequency limit under
F7.28
small torque
Upper frequency limit under small torque: It sets max output frequency under small torque output to keep stable
speed.
Small torque value
F7.29
threshold
Small torque value threshold: While give torque is smaller than this value, the inverter output frequency upper limit is
[F7.28]. It is main function is to keep stable speed under certain small torque.
While it is "0",inverter close this function and stop output. The motor is in free state.
Magnetic powder brake current
F7.30
give channel
LED "0" digit: main channel selection
0: Keyboard give
[F7.31] keyboard No set frequency give or modify
1: Keyboard pot give or modify
2: VS1 give or modify
3: VS2 give or modify
4: AS give or modify
LED "00" digit: Second channel selection
0: Keyboard give
[F7.31] keyboard No set frequency give or modify
1: Keyboard pot give or modify
2: VS1 give or modify
Setting range: Lower limit-Max output
frequency
Setting range: 0.0-20.0%
Setting range: 0.00-50.00Hz
Setting range: 0-200.0% (0:This function off)
Setting range: 0000-4450
112
Function Parameter specifications
Factory set: 50.00
Factory set:0.0
Factory set: 3.00Hz
Factory set: 0.0%
Factory set: 0010H
*

Advertisement

Table of Contents
loading

Table of Contents