AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Terminal action
F2.13
mode
F2.14
Reserved
F2.15
Reserved
PUL input min
F2.16
frequency
PUL min frequency
F2.17
corresponding
setting
PUL input max
F2.18
frequency
PUL max frequency
F2.19
corresponding
setting
F2.20
PUL filter time
PUL cut-off
F2.21
frequency
UP/DW terminal
F2.22
frequency adjust
selection
UP/DW terminal
F2.23
frequency add/dec
speed time
F2.24
Reserved
F2.25
Timer time of unit
F2.26
Timer setting
F2.27
Counter max value
LED "0" digit: free stop terminal reset
mode
0: Reset to original order while invalid
1: Not reset to original order while invalid
LED "00" digit: emergency stop terminal
reset mode
0: Reset to original order while
disconnect
1: Not reset to original order while
disconnect
LED "000" digit: terminal run mode after
fault reset
0: Terminal control to power on
directly
1: Terminal control to power on after stop
LED "0000" digit: reserved
0.0-50.00kHz
0.00-100.00%
0.0-50.00kHz
0-100.00%
0.00s-10.00s
0.000-50.000kHz
0:Off electricity storage
1:Off electricity does not storage
2:Valid in running, clear zero at stop
0.01-50.00Hz/s
0: Second
1: Minute
2: Hour
0-65000
0-65000
152
BASIC OPERATION AND TRIAL RUN
0111
91
92
92
92
0.00kHz
92
0.00%
50.00
92
kHz
92
100.00%
92
0.10s
0.010
92
kHz
92
0
92
0.50Hz/s
93
93
0
0
93
1000
93
0x20D
0x20E
0x20F
0x210
0x211
0x212
0x213
0x214
0x215
0x216
0x217
0x218
0x219
0x21A
0x21B