Veichi AC90 Manual page 123

Tension control frequency inverter
Table of Contents

Advertisement

AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
1: Keyboard pot give or modify
2: VS1 give or modify
3: VS2 give or modify
4: AS give or modify
5: PUL give or modify
6:RS485 give
LED "000" digit: Main channel combines second channel
×
0: Main
[F9.01]
×
1: Second
[F9.02]
×
2: Main
[F9.01]+second
×
3: Main
[F9.01]-second
×
4: MAX {Main
[F9.01], second
×
5: MIN {Main
[F9.01], second
LED "000" digit: Reserved
Tension give main channel
F9.01
gain
Tension give second channel
F9.02
gain
Tension give main channel gain zooms in or out tension values, adjust the main channel tension by ratio.
Tension give second channel gain zooms in or out tension values, adjust the second channel tension by ratio.
F9.03
Tension No setting
While keyboard No give tension channel, it is used to set and modify keyboard No give tention.
F9.04
Max tension
While keyboard No give tension channel, it is max tension inverter permit to set.
F9.05
Tension tape coefficient
It is used to control winding material moulding under winding mode. In winding process, sometime tension needs
reduce while roll diameter increase to make sure good winding moulding.
output tension=set tension
While the tape coefficient is bigger, tension will reduces quicker and quicker as the diameter increase in winding
process. Otherwise, it will be different.While tension tape need adjust. It can be modified by [F9.06] tape compensation
modify.
×
[F9.02]
×
[F9.02]
×
[F9.02]}
×
[F9.02]}
Setting range:0-500.0%
Setting range:0-500.0%
Setting range:0-30000N
Setting range:0-30000N
Setting range:0.0-100.0%
×
1-tension tape×
Initial diameter+Tape compensate modify
1-
Actual diameter+Tape compensate modify
118
Function Parameter specifications
Factory set: 100.0%
Factory set: 100.0%
Factory set: 0
Factory set:0
Factory set:0.0%