F06:Output Terminal - Veichi AC310 Series Manual

Frequency ac drive
Hide thumbs Also See for AC310 Series:
Table of Contents

Advertisement

F05.58
AI2 upper limit
(0x053A)
corresponding setting
F05.59
AI2 filter time
(0x053B)
F05.60
Curve 1 lower limit
(0x053C)
F05.61
Curve 1 lower limit
(0x053D)
corresponding setting
F05.62
Curve 1 inflection point
(0x053E)
1 input voltage
F05.63
Curve 1 inflection point
(0x053F)
1 corresponding setting
F05.64
Curve 1 inflection point
(0x0540)
2 input voltage
F05.65
Curve 1 inflection point
(0x0541)
2 corresponding setting
F05.66
Curve 1 upper limit
(0x0542)
F05.67
Curve 1 upper limit
(0x0543)
corresponding setting
F05.70
Curve 2 lower limit
(0x0546)
F05.71
Curve 2 lower limit
(0x0547)
corresponding setting
F05.72
Curve 2 inflection point
(0x0548)
1 input voltage
F05.73
Curve 2 inflection point
(0x0549)
1 corresponding setting
F05.74
Curve 2 inflection point
(0x054A)
2 input voltage
F05.75
Curve 2 inflection point
(0x054B)
2 corresponding setting
F05.76
Curve 2 upper limit
(0x054C)
F05.77
Curve 2 upper limit
(0x054D)
corresponding setting
F05.80
AI terminal for digital
(0x0550)
input
F05.81
Terminal characteristics
(0x0551)
selection
AI terminal function
F05.82
selection (as X
(0x0552)
terminal)
F05.83
AI high level setting
(0x0553)
4.9 F06:Output Terminal
Parameter
Name
(Address)
AC310 Series Frequency AC Drive Manual
value.
V/F SVC FVC PMVF PMSVC PMFVC
Set the percentage of the corresponding set value
V/F SVC FVC PMVF PMSVC PMFVC
Define the size of the analog signal to be used to eliminate
interfering signals.
V/F SVC FVC PMVF PMSVC PMFVC
Set the lower limit of curve 1
V/F SVC FVC PMVF PMSVC PMFVC
Set the corresponding percentage
V/F SVC FVC PMVF PMSVC PMFVC
Set curve 1 inflection point 1 input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set the corresponding percentage
V/F SVC FVC PMVF PMSVC PMFVC
Set curve 1 inflection point 2 input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set the corresponding percentage
V/F SVC FVC PMVF PMSVC PMFVC
Set the upper limit of curve 1
V/F SVC FVC PMVF PMSVC PMFVC
Set the corresponding percentage
V/F SVC FVC PMVF PMSVC PMFVC
Set the lower limit of curve 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the corresponding percentage
V/F SVC FVC PMVF PMSVC PMFVC
Set curve 2 inflection point 1 input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set the corresponding percentage
V/F SVC FVC PMVF PMSVC PMFVC
Set curve 2 inflection point 1 input voltage
V/F SVC FVC PMVF PMSVC PMFVC
Set the corresponding percentage
V/F SVC FVC PMVF PMSVC PMFVC
Set the upper limit of curve 2
V/F SVC FVC PMVF PMSVC PMFVC
Set the corresponding percentage
V/F SVC FVC PMVF PMSVC PMFVC
0:valid at low level 1:valid at high level
Unit:AI1
Tens:AI2
V/F SVC FVC PMVF PMSVC PMFVC
See the function of the terminal for details.
V/F SVC FVC PMVF PMSVC PMFVC
The input setting is higher than the high level setting, which is the
input high level.
V/F SVC FVC PMVF PMSVC PMFVC
Less than the low level setting is low level.
Content
25
100.00%
RUN
(-100.00~100.00%)
0.010s
RUN
(0.000~6.000s)
0.0%
RUN
(0.0 ~ 100.0%)
0.00%
RUN
(0.00 ~ 100.00%)
30.0%
RUN
(0.0 ~ 100.0%)
30.00%
RUN
(0.00~100.00%)
60.0%
RUN
(0.0 ~ 100.0%)
60.00%
RUN
(0.00~100.00%)
100.0%
RUN
(0.0~100.0%)
100.00%
RUN
(0.00 ~ 100.00%)
0.0%
RUN
(0.0 ~ 100.0%)
0.00%
RUN
(0.00 ~ 100.00%)
30.0%
RUN
(0.0 ~ 100.0%)
30.00%
RUN
(0.00~100.00%)
60.0%
RUN
(0.0 ~ 100.0%)
60.00%
RUN
(0.00~100.00%)
100.0%
RUN
(0.00~100.0%)
100.00%
RUN
(0.00 ~ 100.00%)
0000
RUN
(0000 ~ 1111)
0
STOP
(0~63)
70.00%
RUN
(0.00~100.00%)
30.00%
RUN
(0.00~100.00%)
Factory default
Adjustable