AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
LED"00"digit: Time unit
0: second
1: minute
2: hour
LED"000"digit: Power down save mode
0: no save
1: save
Decide whether save running state while power down. If save, define recover mode by [FC.15] LED "0000" digit.If need
continute the state before power off, this parameter should be set as 1.
LED"0000"digit: Start-up mode
0: Restart from the 1st step
1: Restart from the step where stop
2: Restart from the time when stop
Set restart mode while stop for some reasons (stop, fault, power off and so on).
Output frequency is limited by upper/lowest limitation. While frequency is lower then lowest limitation, it runs
as [F0.13] lowest limitation mode.
FC.16
PLC 1st step running time
FC.17
PLC 2nd step running time
FC.18
PLC 3rd step running time
FC.19
PLC 4th step running time
FC.20
PLC 5th step running time
FC.21
PLC 6th step running time
FC.22
PLC 7th step running time
FC.23
PLC 8th step running time
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
140
Function Parameter specifications
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0