Veichi AC90 Manual page 173

Tension control frequency inverter
Table of Contents

Advertisement

AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
F9.47
Empty to full roll time 2
F9.48
Current time
F9.49
Reserved
F9.50
Reserved
F9.51
Reserved
Malfunction and protection parameters
NO.
Function description
Protection function
FA.00
selection 1
Protection function
FA.01
selection 2
0-65000s
0-65000s
Range of settings and definition
LED "0"digit: ACC over-current
protection selection
0: Invalid
1: Valid
LED"00"digit: DEC over-current
protection selection
0: Invalid
1: Valid
LED"000"digit: current limit selection
while running
0: Invalid
1: Valid
LED"0000"digit: reserved
LED"0"digit:DEC over-voltage
protection selection
0: Invalid
1: rating 1 over-voltage protection
2: rating 2 over-voltage protection
LED"00"digit: RUN over-voltage
protection selection
0: Invalid
1: Valid
LED"000"digit: inverter over-load
action selection
0: emergency stop output and alarm
1: emergency stop and alarm
2: limit current and run
LED "0000" digit: motor over-load act
0: emergency stop output and alarm
1: emergency stop and alarm
2: limit current and run
3: motor over-load protection off
168
BASIC OPERATION AND TRIAL RUN
124
7200
124
*
124
124
124
Factory
Reference
Attribute
setting
page
0001
125
0001
125
0x92F
0x930
0x931
0x932
0x933
Communica
tion add
0xA00
0xA01

Advertisement

Table of Contents
loading

Table of Contents