AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Open-loop VC control(speed mode)
start
If change motor or electrify for the first time,
please self-tuning according to chart 4-14
set F0.00=0,choose VC control mode
set F0.01=0,choose speed control mode
according to chart 4-15,set giving frequency
set F0.02 to choose run command giving channel
according to chart 4-17,set start/stop control
according to system requirement,set F6.11 maximum output torque
trial run
whether control performance
reaches requirment
yes
over
Chart 4-18: Open-loop VC control
BASIC OPERATION AND TRIAL RUN
no
adjust F6 parameters to optimize VC
control performance,to improve output
torque/speed accuracy
46