AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
It sets run frequency of 15 steps in PLC and multistep control.
Mult steps control has priorty only after JOG. While multi steps control, 4 multifunction input terminals are needed to set
as control terminals. Set details refer to [F2.00-F2.07] .
Inverter is running at which step is decides by the ON/OFF state of 4 control terminal and COM . Run and direction is
controlled by run signal and direction gived by [F0.02] . ACC/DEC time default is ACC/DEC time 1 [F0.14] , [F0.15] .Or
select ACC/DEC time by ACC/DEC time selection terminal set by [F2.00-F2.07] .
Multi steps terminal
4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
Multi steps terminal
Multi steps terminal
3
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
K1
K2
K3
K4
K5
K6
terminal connection
Multi steps terminal
2
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
inverte
X1 FWD/STOP
X2 REV/STOP
X3 Multi steps terminal 1
X4 Multi steps terminal 2
X5 Multi steps terminal 3
X6 Multi steps terminal 4
COM
138
Function Parameter specifications
terminal
1
ON
1X [FC.00]
OFF
2X [FC.01]
ON
3X [FC.02]
OFF
4X [FC.03]
ON
5X [FC.04]
OFF
6X [FC.05]
ON
7X [FC.06]
OFF
8X [FC.07]
ON
9X [FC.08]
OFF
10X [FC.09]
ON
11X [FC.10]
OFF
12X [FC.11]
ON
13X [FC.12]
OFF
14X [FC.13]
ON
15X [FC.14]
speed