Veichi AC90 Manual page 146

Tension control frequency inverter
Table of Contents

Advertisement

AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
FC.24
PLC 9th step running time
FC.25
PLC 10th step running time
FC.26
PLC 11th step running time
FC.27
PLC 12th step running time
FC.28
PLC 13th step running time
FC.29
PLC 14th step running time
FC.30
PLC 15th step running time
Set running time of every 15 step. Time unit is decided by [FC.15] LED "00" digit setting.
FC.31
PLC 1st step direction and ADD/DEC time
FC.32
PLC 2nd step direction and ADD/DEC time
FC.33
PLC 3rd step direction and ADD/DEC time
FC.34
PLC 4th step direction and ADD/DEC time
FC.35
PLC 5th step direction and ADD/DEC time
FC.36
PLC 6th step direction and ADD/DEC time
FC.37
PLC 7th step direction and ADD/DEC time
FC.38
PLC 8th step direction and ADD/DEC time
FC.39
PLC 9th step direction and ADD/DEC time
FC.40
PLC 10th step direction and ADD/DEC time
FC.41
PLC 11th step direction and ADD/DEC time
FC.42
PLC 12th step direction and ADD/DEC time
FC.43
PLC 13th step direction and ADD/DEC time
FC.44
PLC 14th step direction and ADD/DEC time
FC.45
PLC 15th step direction and ADD/DEC time
Set running direction and ACC/DEC time of every 15 step while running.
LED "0" digit: this step run direction
0: REV
1: REV
If [F0.07] LED "00" digit is 0 or [F0.16] is 2, and this setting is 1 REV, inverter runs as 0.00Hz.
LED "00" digit: ACC/DEC time in this step
0: ACC/DEC time 1
1: ACC/DEC time 2
2: ACC/DEC time 3
4: ACC/DEC time 4
LED "000" digit: reserved
LED "0000" digit: reserved
FC.46-FC.48
FC.49
Swing frequency control
FC50
Swing frequency pre-set
Pre-set frequency hold
FC.51
time
FC.52
AW
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range: 0.0-6500.0(s/m/h)
Setting range:0000-0031
Reserved
Setting range: 0000-0111
Setting range: 0.00-max frequency
Setting range: 0.00-650.00s
Setting range: 0.0-100.0%
141
Function Parameter specifications
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 10.0
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0000
Factory set: 0.00Hz
Factory set: 0.00s
Factory set: 0.0%

Advertisement

Table of Contents
loading

Table of Contents