9.4 Analog terminal functions
F3.00
VS1 Lowest limit
VS1 Lowest limit
F3.01
corresponding setting
F3.02
VS1 upper limit
VS1 upper limit
F3.03
corresponding setting
F3.04
VS1 filter time
VS1 Lowest limit: It defines signal accepted by analog input terminal (VS1), Inverter deal voltage lower than this value
as lower limit.
VS1 lower limit corresponding setting: It defines ratio of VS1 lower limit.
VS1 upper limit: It defines signal accepted by analog input terminal (VS1), Inverter deal voltage higher than this value
as higher limit.
VS1 upper limit corresponding setting: It defines ratio of VS1 upper limit.
VS1 filter time: It is (VS1) input analog signal filter time to eliminate disturb signal. The longer filter time is, the stronger
anti-disturb force is. The shorter filter time is, the weaker anti-disturb force is. But respond speed will be quicker.
give frequency
F0.09 × F3.03
F0.09 × F3.01
F3.00
Analog give torque and tension, the relationship:
Give torque
F7.06
Input torque
upper limit
F7.07
Input torque
lower limit
F3.00
F3.05
VS2 Lowest limit
VS2 Lowest limit
F3.06
corresponding setting
F3.07
VS2 upper limit
Setting range: 0.00-10.00V
Setting range: 0.00-100.00%
Setting range: 0.00-10.00V
Setting range: 0.00-100.00%
Setting range: 0.00-10.00s
give frequency
F0.09 × F3.03
F0.09 × F3.01
F3.02 Input voltage
Anaiog give frequency show
200% torque
F9.04 Max
tension
Input voltage
F3.02
VS1 analog give torque/tension figure
Setting range: 0.00-10.00V
Setting range: 0.00-100.00%
Setting range: 0.00-10.00V
96
Function Parameter specifications
F3.00
Give tension
F3.00
F3.02
Factory set: 0.00V
Factory set: 0.00%
Factory set: 10.00V
Factory set: 100.00%
Factory set: 0.10s
F3.02
Input voltage
Input voltage
Factory set: 0.00V
Factory set: 0.00%
Factory set: 10.00V