Veichi AC90 Manual page 182

Tension control frequency inverter
Table of Contents

Advertisement

AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Fd.03
Data format
Communication ratio
Fd.04
setting
Communication
Fd.05
answer delay
Communication
Fd.06
overtime time
RS485
Fd.07
communication fault
action mode selection
Transmission
Fd.08
response dispose
Main machine
Fd.09
sending selection
1: (E,8,1) even checkout,
Data digit: 8,
Stop digit: 1
2: (O,8,1) odd checkout,
Data digit: 8,
Stop digit: 1
3: (N,8,2) no checkout,
Data digit: 8,
Stop digit: 2
4: (E,8,2) even checkout,
Data digit: 8,
Stop digit: 2
5: (O,8,2) odd checkout,
Data digit: 8,
Stop digit: 2
0.00-5.00
0-500ms
0.1-100.0s
0: Alarm and stop freely
1: Not alarm, go on run
2: Stop without alarm
0: Write operation with response
1: Write operation without response
LED"0"digit: the first group of transmit
frame selection
0: Invalid
1: Run command given
2: Main machine given
3: Main machine output frequency
4: Main machine upper limit frequency
5: Main machine given torque
6: Main machine output torque
7: Reserved
8: Reserved
9: Main machine given PID
A: Main machine feedback PID
LED"10"digit: the second group of
transmit frame selection Ditto
LED"100"digit: the third group of
transmit frame selection Ditto
LED"1000"digit: the fourth group of
transmit frame selection Ditto
177
BASIC OPERATION AND TRIAL RUN
0
143
1.00
143
0ms
143
1.0s
144
1
144
0
144
0031
144
0xD03
0xD04
0xD05
0xD06
0xD07
0xD08
0xD09

Advertisement

Table of Contents
loading

Table of Contents