AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
E.EEP
LIFE
E.ILF
E.oLF
E.Gnd
E.HAL
E. EF
E.PAn
E. CE
E.CPE
E.ECF
E.PG
Electromagnetic disturb in
Memory fault
memory period.
EEPROM damage.
Reserved
Input side
3-phase input power open
open phase
phase.
Ouput side
3-phase output power
open phase
open phase
Output earth terminal short
Output earth
circuit.
Current
Detect circuit fault.
detection fault
Phase imbalance
Inverter
Peripheral equipment fault
external fault
protection.
Keyboard wire fault.
Keyboard
Keyboard component
connect fault
damage.
Unsuitable baud rate
setting.
Communication wire
Rs485commu
breaks.
nication fault
Communication format
does not match upper
machine.
Parameter copy
Parameter
communication is fault.
copy fault
Copy keyboard is not
match the inverter.
Communication between
extend card and
Extend card
frequency inverter
connection
overtime.
fault
Extend card does not
match frequency inverter.
PG card
PG card and inverter
connection
connection failure
abnormal
BASIC OPERATION AND TRIAL RUN
53
resume load and save.
Seek support from factory.
Seek support from factory.
Check 3-phase power supply
and the phase.
Check 3-phase power supply
wiring.
Check 3-phase output voltage
and current.
Check wiring.
Check wiring and insulation.
Seek for technic support.
Check motor and wiring.
Check peripheral equipment.
Check keyboard wire.
Seek support from factory.
Set suitable baud rate setting.
Check communication wire.
Set right communication format.
Check wire.
Select the specified external
keyboard model.
Check connector, and re-insert
wire.
Choose the named card.
Check the connection