Motor Parameters - Veichi AC90 Manual

Tension control frequency inverter
Table of Contents

Advertisement

AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL

9.6 Motor parameters

F5.00
F5.01
Motor rate
Set it according to nameplate.
F5.02
Motor rated power
Set it according to nameplate based on unit of 0.1kw. While motor rated power setting is changed, inverter will
automatic adjust [F5.03-F5.11] to default. If self-study, [F5.07-F5.11] will automatic change according to the result of
self study. If need high accuracy control, It must self study after right [F5.01-F5.06] setting.
F5.03
Motor rated frequency
Set it according to nameplate.
F5.04
Motor rated speed
Set it according to nameplate.
F5.05
Motor rated voltage
Set it according to nameplate.
F5.06
Motor rated current
Set it according to nameplate.
F5.07
Motor no-load current
It set automatic while self study.
F5.08
Motor stator resistance
It set automatic while self study.
F5.09
Motor rotor resistance
It set automatic while self study.
Motor stator&rotor
F5.10
inductance
It set automatic while self study.
Motor stator&rotor mutual
F5.11
inductance
It set automatic while self study.
Parameters self-adjustment
F5.12
selections
Reserved
Setting range: 2-48
Setting range: 0.4-1000.0kW
Setting range: 0.01Hz-max frequency
Setting range: 0-65000rpm
Setting range: 0-1500V
Setting range: 0.1-2000.0A
Setting range: 0.01-650.00A
Setting range: 0.001-65.000
Setting range: 0.001-65.000
Setting range: 0.1-6500.0mH
Setting range: 0.1-6500.0mH
Setting range: 0-2
103
Function Parameter specifications
Factory set: 4
Factory set: Accord model
Factory set: Accord model
Factory set: Accord model
Factory set: Accord model
Factory set: Accord model
Factory set: Accord model
Factory set: Accord model
Factory set: Accord model
Factory set: Accord model
Factory set: Accord model
Factory set: 0