9.8 Torque control parameter
Torque give source
F7.00
selection
It used to select channel for torque given while torque control.
LED "0" digit: Main channel selection
0: Keyboard number given torque
1: Keyboard potentiometer given
2: VS1
3: VS2
4: AS
5: PUL
6: RS485 communication give
7: Tension control give
LED "00" digit: Second channel selection
0: Keyboard number given torque [F7.01] keyboard number give frequency give and modify main torque
1: Keyboard potentiometer given
2: VS1
3: VS2
4: AS
5: PUL
6: RS485 communication gives
7: Tension control gives
LED "000" digit: Main channel add second channel mode
0: MainX [F7.02] Main channel is valid, Main channel giving value is main channel giving value multiply torque give
main channel gain [F7.02]
1: Second×[F7.03] Second channel is valid, Second channel giving value is second channel giving value multiply
torque give second channel gain [F7.03]
2: MainX [F7.02]+SecondX [F7.03]
[F7.02] add the result of second channel giving value multiply torque give second channel gain [F7.03]. Then sum is
the output torque of the inverter.
3: Main X [F7.02] -Second X [F7.03]
gain [F7.02] minus the result of second channel giving value multiply torque give second channel gain [F7.03]. Then
the result is the output torque of the inverter.
4: MAX{main X [F7.02],second X [F7.03]}
give main channel gain [F7.02] and the result of second channel giving value multiply torque give second channel
gain [F7.03] is the output torque of the inverter.
5: MIN {main X [F7.02],second X [F7.03]}
give main channel gain [F7.02] and the result of second channel giving value multiply torque give second channel
gain [F7.03] is the output torque of the inverter.
LED "0000" digit: Reserved
Keyboard number give
F7.01
torque
Set torque given value by keyboard. While [F4.04] LED "0" digit is 2, the parameter can be modified by UP/DW key.
Whether save modification is decided by [F4.04] LED "00" digit setting. It can adjust torque given value.
Setting range: 0000-0577
[F7.01] keyboard number give frequency give and modify main torque
The result of main channel giving value multiply torque give main channel gain
The result of main channel giving value multiply torque give main channel
The bigger one of the result of main channel giving value multiply torque
The smaller one of the result of main channel giving value multiply torque
Setting range: 0%-200.0%
107
Function Parameter specifications
Factory set: 0000
Factory set: 100.0%