AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL

9.5 Keyboard and display parameters

Parameter and key lock
F4.00
selections
0: Unlock Parameter and keyboard lock function invalid.
1: Parameter lock Lock all function parameter settings, can not modify (except theF0.08). Can not enter into the
parameter setting.All buttons in the keypad are unlocked.
2: Parameter and key lock (except FWD/STOP/JOG) Lock all parameter settings, can not modify. And lock all keys on
keyboard except FWD/STOP/JOG.
3: All parameter and key lock Lock all parameter settings, can not modify. And lock all keys on keyboard except PRG.
Note:
1. 2 lines keypad unlock method: Press "PRG" and 1
move to 2
line,then enter password(F4.01-user password) and press "SET".
nd
2. Single line keypad unlock method: Press "PRG" and show "CodE". Press "SET" then enter
password(F4.01-user password) and press "SET" again and will be clear!
3. User password is a parameter which purpose is to protect the inverter from tampering at will.In order to
avoid bring inconvenience, please keep it confidential!
F4.01
User password
It used to set user password. While [F4.00] is (not 0) lock state, need input this password to unlock. Factory set is 0.
F4.02
REV/JOG selections
0: REV While keyboard control, press this button, inverter reverse run. Key REV/JOG not light.
1: JOG While keyboard control, press this button, inverter JOG. Key REV/JOG light.
F4.03
STOP key function range
LED "0"digit: terminal control
0: invalid to terminal order While terminal given signal, STOP key can not control to stop.
Setting range: 0-3
line show "CodE".And use the "UP"-"DOWN" key to
st
Setting range: 0-9999
Setting range: 0-1
Setting range: 0000-0011
100
Function Parameter specifications
Factory set: 0
Factory set: 0
Factory set: 0
Factory set: 0000