The display content of
F4.11
the first line at the
running state
The display content of
F4.12
the first line at the
stopped state
The display content of
F4.13
the second line at the
running state
The display content of
F4.14
the second line at the
stopped state
Rotate speed display
F4.15
coefficient
LED"0"digit: display the first group
0: Given frequency
1: Output frequency
2: Output current
3: Input voltage
4: Output voltage
5: Machine speed
6: Reserved
7: Output torque
8: PID given value
9: PID feedback value
A: Output power
B: Bus voltage
C: Module temperature 1
D: Module temperature 2
E: ON/OFF state of input terminal X
F: ON/OFF state of input terminal Y
LED"10"digit: display the second group
LED"100"digit: display the third group
LED"1000" digit: display the fourth
group
LED "0" digit: display the first group
LED"00"digit:display the second group
LED"000" digit: display the third group
LED"0000"digit:display the fourth group
LED "0" digit: display the first group
LED"00"digit:display the second group
LED"000" digit: display the third group
LED"0000"digit:display the fourth group
LED "0" digit: display the first group
LED"00"digit:display the second group
LED"000" digit: display the third group
LED"0000"digit:display the fourth group
0.0-5000.0%
157
BASIC OPERATION AND TRIAL RUN
3210
102
3210
102
3210
102
3210
102
100.0%
102
0x40B
0x40C
0x40D
0x40E
0x40F