Veichi AC90 Manual page 95

Tension control frequency inverter
Table of Contents

Advertisement

AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
time 2 coming ture. Details see [F9.46-F9.47].
56: Roll diameter reset terminal
parameter is valid, inverter will back the roll diameter to initial value.
57: Roll diameter calculation pause In diameter calculation, while this parameter is valid, inverter will stop roll
diameter calculation.
F2.08
X1-X4 terminal trait selection
F2.09
X1-X4 input terminal filer time
X1-X4 terminal trait selections
LED "0"digit: X1 terminal
0: On valid
1: Off valid
LED"00"digit: X2 terminal
0: On valid
1: Off valid
LED "000"digit: X3 terminal
0: On valid
1: Off valid
LED"0000"digit: X4terminal
0: On valid
1: Off valid
X1-X4 input terminal filer time: When input terminal state changes, only if changed state keeps after filter time setting,
it is considered as valid terminal state change. Otherwise, it keeps last state to effectively avoid misact caused by
disturbance.
F2.10
X5-X8 terminal trait selection
F2.11
X5-X8 input terminal filer time
Same as F2.08 and F2.09.
F2.12
Terminal control mode
0:2-line 1 Run and direction in 1.Factory set is X1(FWD), X2(REV) terminals decide motor forward or reverse.
K1
0
1
0
1
In diameter calculation, set [F9.18] as "0" (roll diameter manual reset) and this
Setting range: 0000-1111
Setting range: 0.000-60.000s
Setting range: 0000-1111
Setting range: 0.000-60.000s
Setting range: 0-3
run order
K2
0
stop
0
FWD
1
REV
1
COM
0: 2-line 1
frequency inverter
X1
K1
FWD order(run while close)
X2
K2
REV order(run while close)
COM
common input port
90
Function Parameter specifications
Factory set: 0000
Factory set: 0.010s
Factory set: 0000
Factory set: 0.010s
Factory set: 0