Veichi AC90 Manual page 116

Tension control frequency inverter
Table of Contents

Advertisement

AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Upper
frequency limit
selection
0: FWD/REV set by[F0.10]
under torque
control
Give frequency
limit range
Feature
FWD/REV upper/lower limit all setby F0.10
LED "0" digit: Torque control upper frequency limit selection
0: FWD/REV set by [F0.11]. Same as speed control
1: FWD set by LED "00"digit; REV set by LED "000"digit. Used where need set FWD upper/lower limit separately
LED "00" digit: FWD upper frequency limit set
0: Torque control FWD upper frequency limit No set (F7.24) + max frequency
bias.
1: Keyboard pot give +max frequency
2:VS1 give +max frequency
3:VS2 give +max frequency
4: AS give +max frequency
5: PUL give +max frequency
6:RS485 give +max frequency
LED "000" digit: REV upper frequency limit set
0: Torque control REV upper frequency limit No set (F7.26) + max frequency
bias.
1: Keyboard pot give +max frequency
2:VS1 give +max frequency
3:VS2 give +max frequency
4: AS give +max frequency
5: PUL give +max frequency
6:RS485 give +max frequency
Torque control FWD upper
F7.24
frequency limit No set
Torque control FWD upper
F7.25
frequency limit bias
torque control FWD upper frequency limit bias.
*
torque control FWD upper frequency limit bias.
*
torque control FWD upper frequency limit bias.
*
torque control FWD upper frequency limit bias.
*
torque control FWD upper frequency limit bias.
*
torque control FWD upper frequency limit bias.
*
torque control REV upper frequency limit bias.
*
torque control REV upper frequency limit bias.
*
torque control REV upper frequency limit bias.
*
torque control REV upper frequency limit bias.
*
torque control REV upper frequency limit bias.
*
torque control REV upper frequency limit bias.
*
Setting range: Lower limit-Max output
frequency
Setting range: 0.0-20.0%
1: FWD set by LED "00"digit
REV set by LED "000"digit
Set FWD upper/lower limit separately
torque control FWD upper frequency limit
*
torque control REV upper frequency limit
*
111
Function Parameter specifications
Factory set: 50.00
Factory set:0.0