Veichi AC90 Manual page 170

Tension control frequency inverter
Table of Contents

Advertisement

AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
F8.24
ASR(VF) integral time 2
F8.25
ASR(VF) filter time 2
ASR(VF) switch
F8.26
frequency 2
F8.27
ASR(VF) slip limit
Tension control special parameters
NO
Function description
F9.00
Tension setting selection
Tension give main
F9.01
channel gain
Tension give second
F9.02
channel gain
F9.03
Tension No setting
0.01-10.00s
0.000-10.000s
0.00-50.00Hz
0.0-500.0%
Range of settings and definition
LED "0" digit: main channel selection
0: Keyboard No give
1: Keyboard pot give or modify
2: VS1 give or modify
3: VS2 give or modify
4: AS give or modify
5: PUL give or modify
6:RS485 give
LED "00" digit: Second channel
selection
0: Keyboard give
1: Keyboard pot give or modify
2: VS1 give or modify
3: VS2 give or modify
4: AS give or modify
5: PUL give or modify
6:RS485 give
LED "000" digit: Main channel
combines second channel
0: Main×[F9.01]
1: Second×[F9.02]
2: Main×[F9.01]+second ×
[F9.02]
3: Main×[F9.01]-second×[F9.02]
4: MAX{ Main×[F9.01],second×
[F9.02]}
5: MIN{ Main×[F9.01],second×
[F9.02]}
LED "000" digit: Reserved
0-500.0%
0-500.0%
0-30000N
165
BASIC OPERATION AND TRIAL RUN
0.50s
116
0.100s
116
10.00Hz
116
100.0%
117
Factory
Reference
Attribute
setting
page
0000
117
100.0%
118
100.0%
118
0
118
0x818
0x819
0x81A
0x81B
Communica
tion add
0x900
0x901
0x902
0x903

Advertisement