AC90 TENSION CONTROL FREQUENCY INVERTER MANUAL
Control mode: Choose right control mode base on need.The different features as below:
Control
mode
Output frequency range:0-upper limit frequency
Frequency
Output frequency is controlled by giving
and torque
frequency. Output torque equal to load torque.
F6.11 Max
output torque
Torque
range
20% torque
Features
Take motor speed as aim, quick repond to load
and
and keep stable speed. It is suitable where
application
need exact speed.
F0.02
Run command channel
It is channel for inverter receiving run and stop order and run direction. It is only used for starting and stopping control
under torque control.
0: Keyboard control Inverter run and stop is controlled by keyboard key FWD, REV/JOG, STOP/RESET. REV/JOG
key is defined as reverse while [F4.02] set as "0" and jog while [F4.02] set as "1". Please refer to details of [F4.02].
1: Terminal control Factory default as two line mode 1 control mode. Under two line mode 1, inverter run, stop and
direction is controlled by whether "FWD" or "REV" set for [F2.00-F2.07] "multi function input terminal" connects to
control board terminal (COM) or not. "FWD" and "REV" definition refer to [F2.00-F2.07]. While under other control mode,
run, stop and direction refer to [F2.12].
2: RS485 communication control Inverter run, stop and direction is controlled by the signal received by RS485
communication terminal. Details refer to FD communication control parameter group and appendix 2: RS485
communication protocol.
3: Optional card Inverter run, stop and direction is controlled by the signal received by optional card input signal. For
the optional card installation, parameter setting and soon, please refer use manual packing with the optional card.
Note: 1. While fault reset, key STOP/RESET, control terminal reset order and RS485 communication terminal are
valid reset order.
2. While inverter input frequency is 0Hz or lower than min output frequency [F1.26]. As long as you input
run order, keyboard FWD indicator will be on, the motor will run as 0 frequency.
Clew: keyboard key STOP/RESET function can be selectable. Under exterior terminal control or communication
control, it can be defined as stop function. Please refer to [F4.03]. Under exterior terminal control, if use
STOP/RESET to stop, inverter stops and close exterior terminal run order. It needs to input exterior
0: Speed mode
250% torque
Torque
Torque range under speed mode
Setting range: 0-3
Output frequency range:0-upper limit frequency
Output frequency is not only limitedby giving
frequency, but also the load torque. While the
out torque is bigger than the giving torque,
frequency will reduce. Otherwise, the frequency
is milited by the giving frequency.
Torque
F7.06 upper
torque limit
F7.07 lower
torque limit
Torque range under torque mode
Take motor output torque as aim; keep stable
speed while with multi roll diameter calculation
functions. It can be for constant tension and
with tape winding and unwinding.
73
Function Parameter specifications
1: Torque mode
200% Torque
Factory set: 0