4.10 F07 :Operational Control
Parameter
Name
(Address)
F07.00
Start mode
(0x0700)
F07.01
Start pre-excitation
(0x0701)
time
F07.02
Starting frequency
(0x0702)
F07.03
Start protection
(0x0703)
selection
F07.05
Direction of rotation
(0x0705)
F07.06
Power failure restart
(0x0706)
action selection
F07.07
Power failure restart
(0x0707)
waiting time
F07.1x:Stop Control
Parameter
Name
(Address)
F07.10
Stop mode
(0x070A)
F07.11
Shutdown detection
(0x070B)
frequency
F07.12
Stop and restart limit
(0x070C)
time
Insufficient lower limit
F07.15
frequency action
(0x070F)
selection
F07.16
Zero speed torque
(0x0710)
retention factor
F07.17
Zero speed torque
(0x0711)
holding time
F07.18
Positive reversal dead
(0x0712)
time
F07.2x:DC Breaking and Speed Tracking
Parameter
Name
(Address)
AC310 Series Frequency AC Drive Manual
Content
V/F SVC FVC PMVF PMSVC PMFVC
0: started by the start frequency
1: DC braking first starts again from the starting frequency
2: Start after the speed tracking and direction judgment
V/F SVC FVC PMVF PMSVC PMFV
Only asynchronous machine vector control (without PG) supports
pre-excitation, other ignore
V/F SVC FVC PMVF PMSVC PMFVC
When the given frequency is less than this value, it does not start
and is in standby state
V/F SVC FVC PMVF PMSVC PMFVC
0: off 1: on
Unit: terminal start protection when exiting abnormal
Tens: Jog terminal start protection when exiting abnormal
Hundreds: terminal start protection when the command channel is
switched to the terminal
Note: When the free stop, emergency stop, and forced stop
commands are valid, the terminal start protection is enabled by
default, and the protection time is reported as A.RUNx warning.
V/F SVC FVC PMVF PMSVC PMFVC
Unit: running direction
0:Direction unchanged 1:Direction reversed
Tens:running direction selection
0:allow Fwd and Rev commands
2:Rev command only
Hundreds:Frequency control command
0:command is invalid 1:command is valid
V/F SVC FVC PMVF PMSVC PMFVC
0:Invalid
1:Valid
V/F SVC FVC PMVF PMSVC PMFVC
Set the power failure restart waiting time
Content
V/F SVC FVC PMVF PMSVC PMFVC
0: Deceleration stop 1: Free stop
V/F SVC FVC PMVF PMSVC PMFVC
When decelerating to stop, when the AC Drive output frequency is
less than this value, it will enter the stop state.
V/F SVC FVC PMVF PMSVC PMFVC
Waiting time after restarting after shutdown
V/F SVC FVC PMVF PMSVC PMFVC
0 : Run according to frequency command
1 : Free running stops, enters the pause state
2 : Run at the following limited frequency 3 : Zero speed operation
V/F SVC FVC PMVF PMSVC PMFVC
Set zero speed torque current, 100.0% corresponds to AC Drive
rated current
V/F SVC FVC PMVF PMSVC PMFVC
Set zero speed torque hold time
V/F SVC FVC PMVF PMSVC PMFVC
Fwd and Rev switching, zero frequency maintenance time
Content
29
Factory default
(0.00~60.00s)
(0.00~upper limit
frequency setting)
(0000~1111)
1:Fwd command only
(0000~1121)
(0.00~60.00s)
Factory default
(0.00~upper limit
frequency setting)
(0.00~60.00s)
(0.0~150.0%)
(0.0~6000.0s)
(0.0~120.0s)
Factory default
Adjustable
(range)
properly
0
STOP
(0 ~ 2)
0.00s
STOP
0.50Hz
STOP
0111
STOP
0000
STOP
0
STOP
(0 ~ 1)
0.50s
STOP
Adjustable
(range)
properly
0
RUN
(0 ~ 1)
0.50Hz
RUN
0.00s
STOP
0
RUN
(0~3)
60.0%
RUN
0.0s
RUN
0.0s
STOP
Adjustable
(range)
properly