Chapter 3 Reflectometry measurements
Configuring the reflectometry test
Table 2
Reflectance
ORL
WarningThis menu lists possible minor alarm thresholds that the
user could select. If results are between those thresholds and the
«fail» thresholds, they will be highlighted in yellow in the table of
results, and the icon
Thresholds can be set for: Splice / Connector / Reflectance.
If all the results lie within the thresholds (no result is in red or yellow),
results are displayed in green in the table and the icon is

Configuring the Analysis parameters

In the Setup page, press Analysis softkey (if one parameter is selected in
the current screen, press Top Menu soft key to display the right menu keys
and click on Analysis).
The Analysis Setup page is divided into two parts: the Parameters box and
the Measurement box.
Parameters
Section Attenuation
dB/km
dB
42
Multimode Modules
Default
> - 35 dB
< 27 dB
Displays the section slope in the table of results. When the
fiber is too short to measure the slope accurately, no value
is displayed (empty field).
Displays the section Loss in the table of results. With short
fiber where the slope cannot be measured with a good
accuracy, the loss in dB is approximate and displayed.
User Manual
TIA-568C & ISO/IEC 11801
-
-
will appear at the top right of the screen.
78000010220 Rev. 023
.