Page 1
6000A V2 Platform Compact Network Test Platform for installation, commissioning, maintenance and troubleshooting of fiber networks User Manual...
Page 3
6000A V2 Platform Compact Network Test Platform for installation, commissioning, maintenance and troubleshooting of fiber networks User Manual Viavi Solutions 1-844-GO-VIAVI www.viavisolutions.com...
Page 5
In the European Union, all equipment purchased from Viavi after 2005-08-13 can be returned for disposal at the end of its useful life. Viavi will ensure that all waste equipment returned is reused,...
Page 6
It is the responsibility of the equipment owner to return the equipment to Viavi for appropriate disposal. If the equipment was imported by a reseller whose name or logo is marked on the equipment, then the owner should return the equipment directly to the reseller.
..... . . 2 About the 6000A V2 Platform ........3 Main features .
Page 8
Unpacking the instrument Installing and removing a plug-in unit in the 6000A V2 ........12 Platform .
Page 9
Table of Contents ....26 Display of results and commands ... . . 26 Result of the measurement in progress .
Page 10
Establishing connection ..64 Connecting the 6000A V2 Platform and the PC ....64...
Page 11
Connection via a local network . 80 Accessing the internal memory of the 6000A V2 Platform ......81 Sending files by mail .
Page 12
Principle and prerequisites of the Cloud Storage Configuring and connecting to Cloud Storage on the 6000A V2 ........90 Platform .
Page 13
Transferring the 6000A V2 Platform interface via WIFI on a ......... . .114 .
Page 14
Table of Contents Chapter 15 Options and accessories References of options for the 6000A V2 Platform mainframe ..134 References of scopes and associated accessories ......134...
Page 15
Interpreting alarms Formatting the USB memory stick onto the 6000A V2 Platform ......155 Erase disk/harddisk .
Page 16
Table of Contents User Manual 76100000200 Rev. 001...
About This Guide The 6000A V2 Platform of Viavi provides a handhled modular platform designed for the construction, turn-up and maintenance of fiber networks. The topics discussed in this chapter are as follows: – “Purpose and scope” on page xviii –...
About This Guide Purpose and scope Purpose and scope The purpose of this guide is to help you successfully use the 6000A V2 Platform features and capabilities. This guide includes task-based instructions that describe how to install, configure, use, and troubleshoot the 6000A V2 Platform.
Page 19
About This Guide Conventions Table 1 Typographical conventions (Continued) Description Example Text you must type exactly as Type: in the dia- a:\set.exe shown appears in this log box type- face. Variables appear in this type- Type the new hostname face. Book references appear in this Refer to Newton’s Telecom typeface.
Page 20
About This Guide Conventions This symbol represents a risk of electrical shock. NOTE This symbol represents a Note indicating related information or tip. This symbol, located on the equipment or its packaging indicates that the equipment must not be disposed of in a land- fill site or as municipal waste, and should be disposed of according to your national regulations.
6000A V2 Platform Overview Chapter 1 This chapter provides a general description of the 6000A V2 Platform. Topics discussed in this chapter include the following: – “About the 6000A V2 Platform” on page 2 – “Main features” on page 3 –...
Chapter 1 6000A V2 Platform Overview About the 6000A V2 Platform About the 6000A V2 Platform The MTS/T-BERD 6000A V2 is a multiple layer test platform. It allows to manage Fiber Optics Modules, but also Multiple Services Application Modules (SDH/SONET, Ethernet and Triple Play).
Chapter 1 6000A V2 Platform Overview Main features Main features The 6000A V2 Platform is equipped with the following elements: – One protection cover – 8 inch TFT color touchscreen, high visibility (optimized for outdoor use), – RJ45 plug for Ethernet interface –...
Page 24
Open all user documentations included into the 6000A V2 Platform – Update the 6000A V2 Platform firmware – Remote the screen of the 6000A V2 Platform onto a PC and issue commands from the keyboard of the PC – Indicators...
All these functions, except , depend on the modules used and the measurements made: refer to the user manuals of the corre- sponding modules of the 6000A V2 Platform. The direction keys have two principal functions: – on the Results page, they are used to move the cursors or modify the zoom factor.
Chapter 1 6000A V2 Platform Overview Hard keys and indicators Front panel The 6000A V2 Platform is equipped with three indicators, lit into a indicators different color according to the status of the equipment. Table 6 Indicators Status On indicator...
Safety information Chapter 2 This chapter gives the main information on the safety conditions when using the 6000A V2 Platform: – “Battery and AC/DC safety information” on page 8 – “Precautions relating to optical connections” on page 8 – “Laser Safety instructions” on page 9 User Manual 76100000200 Rev.
If another adapter, cord or battery is used, it may damage the 6000A V2 Platform itself. Using the 6000A V2 Platform with a battery other than the one supplied by the manufacturer of the 6000A V2 Platform may entail risks of fire or explosion.
The optical connectors must therefore be clean and dust-free. If the optical connection is not being used, protect the connections of 6000A V2 Platform using the protective caps. Laser Safety instructions The provisions contained in two standards define the safety procedures...
Page 30
Chapter 2 Safety information Laser Safety instructions Measurements on optical fibers are difficult to execute and the precision of the results obtained depends largely on the precautions taken by the user. User Manual 76100000200 Rev. 001...
The topics discussed in this chapter are as follows: – “Unpacking the instrument” on page 12 – “Installing and removing a plug-in unit in the 6000A V2 Platform” on page 12 – “Choosing the position of the instrument on the work surface” on page 13 –...
Remove the 6000A V2 Platform and its accessories from the packing case. Check that the module and accessories ordered are all there. If any part is missing or damaged please contact your local Viavi agent. At the equipment delivery, the following elements are available: –...
Carefully slide the plug-in out of its slot. Choosing the position of the instrument on the work surface Depending on the conditions of use of the 6000A V2 Platform, the instru- ment may be placed on a flat surface or held in the hand.
«standing» user position. Charging the battery Connecting the At the top of the 6000A V2 Platform (upper left-hand corner), lift up mains adapter the power supply socket protector and plug in the mains adapter. Connect the adapter to the mains.
If the Platform is powered to mains, the battery will charge. Platform The On indicator pass from blinking to solid green. The Viavi logo appears on the screen briefly, then an autotest is carried out. The equipment is ready to be used once all the applications are installed.
Next time the key is pressed, they are recalled. Resetting the If the 6000A V2 Platform freezes, prolonged pressure (about 4 s.) on the 6000A V2 key will reset the instrument Platform User Manual...
“Displaying the System Settings screen” on page 18 – “Defining the regional settings of the system” on page 19 – “Defining the screen parameters of the 6000A V2 Platform” on page 20 – “Defining the Automatic shutdown of the 6000A V2 Platform” on...
Chapter 4 Configuring the 6000A V2 Platform Displaying the System Settings screen Displaying the System Settings screen To display the System Settings screen, you must: Press the H hard key to reach the Home page. Fig. 7 Home page Press the menu key System Settings to open the System Settings screen.
Defining the regional settings of the system Defining the regional settings of the system When the 6000A V2 Platform is delivered, it is automatically configured with the System Settings set by default in factory, especially the language and date/time (Language: English / Date format: dd/mm/yyy / Time format: 24 hours clock).
– Min backlight level: -5 – Max backlight level: +5 If the 6000A V2 Platform is operating on battery, it is advisable to choose a minimum lighting level, acceptable for the user, to keep endurance as long as possible. Contrast...
Screen Saver Click on Screen Saver if you wish to activate a screen saver to the equip- ment, to extend the life of the battery, in case the 6000A V2 Platform is not used for some time. Instead of the normal screen, a small animated picture of the 6000A V2 Platform is displayed on the blackened screen.
5, 10 or 30 minutes. Select if the 6000A V2 Platform must not be switched off, even if there is inactivity on the equipment. User Manual 76100000200 Rev. 001...
Page 43
Power meter, VFL (Visual Chapter 5 Fault Locator) & Talkset A variety of built-in optical options are available when ordering. See references in Chapter 15 “Options and accessories” page 131, for details. The topics discussed in this chapter are as follows: –...
«Reference Value» function. Using the Power meter The power meter function is an option chosen at the time of order and incorporated into the 6000A V2 Platform in the factory. To activate the function: Press the button...
Chapter 5 Power meter, VFL (Visual Fault Locator) & Talkset Using the Power meter Configuring the power meter Configuring The measurement parameters can be accessed with the key. ETUP measurement parameters Fig. 11 Configuration of power measurement Wavelength Selecting wavelength: - Auto: the wavelength of the input signal will be automatically detected and selected to perform the measurement:...
Chapter 5 Power meter, VFL (Visual Fault Locator) & Talkset Using the Power meter Attenuator compensation Choice of level to be applied to the wavelength chosen for measurement to compensate for the loss due to the external attenuator (+XX.XX dB). First use the direction keys to choose the wavelength, then press >...
Chapter 5 Power meter, VFL (Visual Fault Locator) & Talkset Using the Power meter Table of results For one and the same fiber, the power meter displays a table of 9 results corresponding to the different possible wavelengths. The first 4 results are displayed on the screen;...
Chapter 5 Power meter, VFL (Visual Fault Locator) & Talkset Using the Power meter – Standard Reference Selects the current result as reference value to measure the attenuation of a link. This reference is displayed under the measure- ment result until a new reference value is chosen.
Chapter 5 Power meter, VFL (Visual Fault Locator) & Talkset VFL Function Fix the plug over the optical input of the power meter so that no light can reach the photodiode of the power meter. If the zero adjustment is made without this plug, an error message may be displayed, as the photodiode will detect too much light.
Store trace. Two files are being saved : – The first file is used with the 6000A V2 Platform and allows to retrieve all measurement results. It is saved with the extension «.Lts». – The second file is a ASCII file using tabulations to separate values.
Each end of the optical link must be provided with a 6000A V2 Platform equipped with the Talkset option. NOTE It is possible to use the talkset of the 6000A V2 Platform and to carry out measurements at the same time, on a different fiber. NOTE It is possible to use the Data transfer feature while using the optical telephone of the 6000A V2 Platform.
Adjusting The sound is transmitted to the earphones of the headset and, if this function has been activated, to the speaker in the 6000A V2 Platform volume level base. To activate the base loudspeaker and adjust the volume: Press the key.
Headset Volume (from 0 to 100). Disconnection When communication is over, deactivate the Talkset/Datalink function on one of the 6000A V2 Platform. This deactivation can be done by either 6000A V2 Platform. Then, the fiber used for Talkset can be disconnected safely.
Page 54
Chapter 5 Power meter, VFL (Visual Fault Locator) & Talkset Remote screen function via Talkset Your screen is now fully replaced by the distant screen, and every- thing you do on your 6000A V2 Platform is in fact done on the distant 6000A V2 Platform. An icon appears in the top banner of the 6000A V2 Platform.
Scope Chapter 6 The scope function is a hot-plug feature enabled directly when inserting a Viavi scope supplied as an accessory (see "References of accesso- ries" page 134). The topics discussed in this chapter are as follows: – "Scope feature" page 36 –...
Before using the P5000/P5000i scope, make sure the Bluetooth option has not been activated, even once, after the start of the MTS/ T-BERD 6000A V2. If it has been activated, stop and restart the equipment before using the P5000/P5000i Scope.
Chapter 6 Scope Configuring the P5000i Scope Configuring the P5000i Scope Scope Plug in your Viavi scope into a USB port from the 6000A V2 Plat- form. connection Push the button YSTEM Validate the Scope function Connect probe with the fiber being inspected.
Chapter 6 Scope Configuring the P5000i Scope Once the line is selected, you can also add a new profile, clicking on the Add Button (see "Adding a new profile" page 40). On the line Tip, select the tip set onto the scope to connect fiber for inspection.
Chapter 6 Scope Configuring the P5000i Scope Fiber The Fiber box allows to configure the fiber plugged to the scope. On the line Fiber Id, enter a name for the fiber using the edition menu displayed via the right direction key. On the line Fiber Number, use the numeric keypad, which will display by clicking on the right arrow key, to enter the fiber number.
The profile must be created via FiberChek2 , and stored on one storage media of the MTS/T-BERD 6000A V2 (disk, hard disk or USB memory stick). On the Setup screen, select Profile and press Add key.
Chapter 6 Scope Starting up with the scope Starting up with the scope Once the FiberScope icon is validated: Press R hard key ESULTS Focus level for image sharpness Fig. 18 Example of the result using the P5000i scope Use the Focus Control button onto the P5000i scope (see Figure 14 on page 36) to adjust the image quality and sharpness.
Chapter 6 Scope Launching a test of the connector and fiber end-face High Mag. / Low The High Mag./Low Mag. menu key allows to switch the display from Mag. High to Low magnification and vice-versa. This function is also available pressing the button directly on the P5000i (see Figure 14 on page 36).
Chapter 6 Scope Launching a test of the connector and fiber end-face Summary of Test results Test result in High mag. Fig. 19 Test results A summary of test results is displayed on the right, upper part of the screen. –...
Chapter 6 Scope Launching a test of the connector and fiber end-face Mosaic Mode It is possible to display only one picture in full screen (640 * 390 pixels) or up to four pictures (320*180 pixels each, including the live camera picture) in mosaic mode.
Chapter 6 Scope Launching a test of the connector and fiber end-face High mag./Low mag. Allows to switch all the images from high to low magnification and vice-versa. This key is not available with jpg files other than those resulting from scope application.
File menu Click on Load Recognized pictures are images resulting from the Scope option and saved on disk via the 6000A V2 Platform. Some pictures resulting from the Scope option may appear nevertheless unrecognized, if they have been stored with a different Scope application, or if the JPG file has been opened and modified under another JPG editor.
Page 67
Chapter 6 Scope File menu Display of the report Once the report has been generated: Press F hard key On the right menu keys, press Load soft key. In the File Explorer, select the pdf report just created. Press Load. Logo, company &...
Page 68
Chapter 6 Scope File menu User Manual 76100000200 Rev. 001...
Several desktop applications are provided to you, thanks to the integra- tion of free software released under the free licences (GPL, LGPL, BSB or other). Their purpose is to bring more functionality to the 6000A V2 Platform. Viavi doesn’t provide any warranty or support regarding these free software.
Chapter 7 Applications PDF viewer PDF viewer Opening a PDF The simplest way to open a pdf file is to press . Select Explorer, look for your file and then select Load >Confirm Load to load the corre- document sponding file. The file opens automatically in the PDF viewer. Another way used to open a pdf document is to press S >...
Chapter 7 Applications Text Editor Text Editor The Text Editor application allows to enter text on the 6000A V2 Platform and save it into a txt file Text Editor To open the Text editor: page In the Home page, press the App’s key In the Application screen, select the icon Text Editor.
This allow to store the characters with your writing characteristics, in order to get the good letters when writing with the stylus.= Saving the text Once the text is entered, you can save it in a file onto the 6000A V2 Plat- form. in a file Click on File >...
Home page, and keep the application active. Web browser Configuring the Before using the Web Browser onto the 6000A V2 Platform, check/ modify the proxy configuration in the System Settings page: Web access On the Home page, press System Settings menu key Select Use proxy parameter in the I/O Interfaces box –...
Once the Web Browser is displayed, you must enter the internet address. internet page Set the cursor in the address bar: Use the mouse connected via USB port on the 6000A V2 Plat- form or the mouse of the PC if the screen is deported via VNC application on the PC.
Chapter 7 Applications Web browser Fig. 27 Internet page opened with the Web Browser Navigation into Once the Web Browser is open, push the key to display on the right of the screen, the buttons used to navigate. the Web Browser Icon Definition...
NOTE The web browser will open a PDF document, not a URL including a PDF file. The PDF is also automatically saved on the disk of the 6000A V2 Platform. Leaving the Depending on how long you want to leave the web browser and on your...
Web browser application menu: click on the key Calculator A calculator can be displayed and used onto the 6000A V2 Platform. In the Home page, press the App’s key In the Application screen, select the icon Calculator. The Calculator opens Fig.
Page 78
Chapter 7 Applications File Explorer User Manual 76100000200 Rev. 001...
Stratasync Chapter 8 This chapter describes how to synchronize your 6000A V2 Platform to the Stratasync application. The topics discussed in this chapter are as follows: – "Principle and prerequisites of the Stratasync" page 60 – "Configuring and synchronizing the 6000A V2 Platform" page 61 User Manual 76100000200 Rev.
The user must have subscribed to Stratasync, and by consequence, he must have acquired an account Identifier and a password. The Ethernet and Proxy parameters must have been correctly configured in the System Settings page of the 6000A V2 Platform (see “Ethernet > Mode” on page 65 “Proxy >...
Chapter 8 Stratasync Configuring and synchronizing the 6000A V2 Platform Configuring and synchronizing the 6000A V2 Platform The 6000A V2 Platform can be configured to be synchronized with the Stratasync. Press Settings in the Home page Check the configuration of the Ethernet and Proxy parameters.
Chapter 8 Stratasync Configuring and synchronizing the 6000A V2 Platform Connecting the Once 6000A V2 Platform is configured in the System Settings page: 6000A V2 Press Expert Tools > Upgrades menu keys. Platform to Press Stratasync menu key Stratasync The synchronization with Stratasync starts...
Chapter 9 Platform Interface The 6000A V2 Platform can be used in combination with a PC in order to transfer the Platform Interface onto a PC, or to access the internal memory or USB memory stick contents on the PC.
Chapter 9 Transferring the 6000A V2 Platform Interface Establishing connection Establishing connection The connection between 6000A V2 Platform and the PC can be done directly, or via a local network. The transfer of the interface can be done using a VNC window on PC.
Page 85
Enter the current password in the Edition keypad and press Enter to validate. Enter the new password and press Enter to validate. Ethernet > Mode Parameters of the local Ethernet network to which the 6000A V2 Platform is connected: Config 1 to 4 static mode enabling input of the configuration of 4 sites.
Page 86
Chapter 9 Transferring the 6000A V2 Platform Interface Establishing connection NOTE Once the 6000A V2 Platform is connected to the network, the icon displays for few seconds and indicates the connection is working. Ethernet IPv6 > Mode The Ethernet IPV6 parameters must be configured to get Ethernet access in accordance with the IPV6 standards.
Fig. 36 Example of configuration for Ethernet Wait about 10 seconds the connection is established. The 6000A V2 Platform Interface can now be transferred onto the PC, or the internal memory/USB key contents can be transferred on PC. Transferring the Interface...
Chapter 9 Transferring the 6000A V2 Platform Interface Virtual control buttons bar You can use keyboard mouse of the PC to control the 6000A V2 Platform (see “Equivalence between the keyboard and 6000A V2 Platform” on page 68). NOTE Once Remote screen is accessbile via VNC, the icon...
Page 89
The Export function is available onto the Platform pressing simultane- ously the left and right arrow keys. NOTE Those equivalences are also valid with a keyboard directly connected to the 6000A V2 Platform via one USB port. User Manual 76100000200 Rev. 001...
Page 90
Chapter 9 Transferring the 6000A V2 Platform Interface Equivalence between the keyboard and 6000A V2 Platform User Manual 76100000200 Rev. 001...
File management Chapter 10 The files management with the 6000A V2 Platform can be performed, wether a module is set onto the equipment or not. The topics discussed in this chapter are as follows: – “File Explorer Overview” on page 72 –...
Chapter 10 File management File Explorer Overview File Explorer Overview To reach the File Explorer page On the Home page, press App’s softkey. Validate the File Explorer icon. The File Explorer page appears. Fig. 39 File Explorer page Directories and Files selections Directory To select a directory from the explorer page: selection...
Chapter 10 File management Directories & Files editing functions Files selection To select one or several files from the explorer page: Press on files that must be selected. To select a list of files using the keys of the Platform: Select and validate the first file of the list (underlined in red) Set the cursor on the last file of the list (underlined in blue) Maintain the right direction key...
Chapter 10 File management Working with directories and files from the explorer Press Copy to keep the directory / file(s) to their initial location. Press Cut to delete the directory / file(s) from their initial location On the left of the screen, select the directory; or select the new storage media.
If different types of files have been selected in the Explorer, only the last one selected will open. File Types For files recognized by the 6000A V2 Platform, the types are symbolized by icons. E.g. Icon Type of FO file OTDR file (.SOR extension)
Text file (.TXT extension) License file (.LIC extension) CSV file (.CSV extension) With the 6000A V2 Platform, you can open and load any kind of Fiber Optic files (OTDR, OSA, PON...) even if the corresponding module is not installed. Sorting files...
6000A V2 Platform. with the USB cable Establishing Connect the 6000A V2 Platform to a PC, plugging the USB cable on connection 6000A the mini USB port of the Platform toward a USB port on the PC. V2 Platform <-> PC...
Remove the mini USB plug from the 6000A V2 Platform USB port. Transferring Il is possible, from a PC, to access the internal memory of the 6000A V2 Platform or to the USB memory stick connected to the Platform by means files to/from a of the FTP server of the 6000A V2 Platform.
Page 99
( ); if not, click to select it. Fig. 46 Internet Protocol Click on Ok and close all the dialog boxes opened onto the PC. On the 6000A V2 Platform, in the System Setup page, under I/O interface > Ethernet, select Dynamic. User Manual 76100000200 Rev. 001...
Accessories > Dos Prompt, type ipconfig", then Enter. Note the IP address and the mask of the PC’s sub-network. Plug the RJ 45 connector of the 6000A V2 Platform into a hub or Ethernet switch with an Ethernet cable (see Figure 45 on page 79).
Explorer, select one / several files and click on Copy, then click on Paste on PC to transfer file Sending files by The 6000A V2 Platform can send files (traces or others) via e-mail, from mail the Explorer. User Manual...
From.Use the button to enter into an edition window. If Sender Mode is set to Auto, any reply to an e-mail sent by the 6000A V2 Platform will be lost. Relay Mode Auto or Manual.
Sent. Click on any key to follow. Creating a screenshot You can create captures of what is displayed on the screen, directly from the 6000A V2 Platform. Configuring the To configure the screenshot and choose the format of the generated file:...
Name of the The screenshot is saved in a file, which is automatically named as follow: screenshots – Print_date (year/month/day)_time (hour/minut/second).jpg/png/pdf files Fig. 51 Example of screenshot, open in the Web Browser of the 6000A V2 Platform User Manual 76100000200 Rev. 001...
Chapter 10 File management Creating a report Creating a report Once the results page of a function is opened (example: OTDR trace, Power Meter results...), it can be exported in a report, using the 6000A V2 Platform. Configuring the To configure the report and choose the format of the report file: report On the Home page, press System Settings key to reach the System Settings page.
Chapter 10 File management Creating a report For OTDR traces – if the function is set to the Trace mode (Trace is selected on the menu key Trace/Summary), the JPG/PNG/PDF file will contain the header and the trace (in one page). –...
The pdf files that can be merged are those generated via the Fast Report key on trace results page or via the E hardkey of the XPORT 6000A V2 Platform (see “Creating a report” on page – The txt files that can be merged are those saved with the results trace (see OTDR Modules User Manual: E8100M02).
“Renaming a directory / file” on page 74). Storage media For saving or recalling data, the 6000A V2 Platform offers a wide choice of media, both built-in and external. Free space on selected media is clearly displayed at the bottom of the left panel.
Chapter 10 File management Storage media The 6000A V2 Platform can also be delivered with a hard disk, available on option, which maximum capacity is of 100GB. It must be used with Transport applications. External USB The 6000A V2 Platform is equipped with 2 USB ports as standard. One...
Cloud Storage The cloud storage onto a 6000A V2 Platform allows to transfer the files from the Platform toward a distant server and vice-versa. Before configuring the Cloud Storage on Platform, you must first create an account on a Cloud Platform on internet.
Page 111
Fig. 55 Example of configuration Connecting Cloud Storage Once configuration has been established on the 6000A V2 Platform, it is ready to be connected with Cloud server: Select one parameter of the Cloud Storage window on 6000A V2 Plat- form...
Chapter 10 File management Storage media Transferring files Once connection between 6000A V2 Platform and cloud storage server is successfully established, the files can be transferred from one Platform using Cloud to the other. Storage Press H hard key. Press FILE Explorer on the Home page In the Explorer page, a new storage media is available: cloud- storage.
Chapter 10 File management Storage media Abbreviations The abbreviations used in the explorer for the different storage media for storage are: media Abbreviation Storage medium disk Internal flash memory harddisk Internal harddisk (option) usbflash USB memory stick cloud-storage Cloud storage media available on PC bluetooth-inbox Bluetooth storage media (option) a.
Page 114
Chapter 10 File management Storage media User Manual 76100000200 Rev. 001...
Smart Access Anywhere Chapter 11 The 6000A V2 Platform can be accessible to any network test locations, using a specific function: Smart Access Anywhere. This function allows one distant user, on a PC, to transfer the Platform Interface and work on 6000A V2 Platform or to access the internal memory / USB memory stick contents on the PC and perform files transfer from T-BERD/MTS to PC and vice-versa.
Ethernet Cable. connection Fig. 57 Ethernet connection The WIFI connection can be used to access to 6000A V2 Platform from any location. This connection is available exclusively if the WIFI option is installed onto the T-BERD/MTS-6000A V2 which will be seen remotely.
USB/WIFI To access to a Platform remotely, the connection between the unit and connection the Viavi application can be established via a USB cable or WIFI, and through a 3G Smartphone, having Internet Sharing capability via USB or through 3G WIFI.
Chapter 11 Smart Access Anywhere Pre-requisite for using the Smart Access Anywhere Application Pre-requisite for using the Smart Access Anywhere Application To access to a 6000A V2 Platform from any locations, specific require- ments are mandatory: – a licence installed on Platform which will be accessible from any locations.
Warning message of a new version available Launching the SmartAccess Anywhere application Once connection is configured, the SmartAccess Anywhere application can be launched On 6000A V2 On the Home page, press Expert Tools Platform Press Access Anywhere menu key The connection to SmartAccessAnywhere Server is in progress.
Launching the SmartAccess Anywhere application Fig. 63 Connection to SmartAccessAnywhere Server in progress Once connection is established with the server, the 6000A V2 Plat- form displays a message with the code to be used to access to the equipment remotely. Fig. 64...
– transfer files from the equipment toward the PC, and vice-versa. Transferring the To display the remote 6000A V2 Platform onto the PC: interface onto On the Introduction page, click on the PC On the left menu, click on...
Page 122
You may click on any of these buttons to obtain exactly the same results than using the hard keys on the front panel of the 6000A V2 Platform. You can use keyboard mouse of the PC to control the 6000A V2 Platform.
Save and quit (Exit) Enter Quit without saving (Abort) Escape a. The Export function is available directly on the 6000A V2 Platform pushing simultaneously the left and right arrow keys. Transferring To work on files (onto PC and onto unit):...
At the bottom of the screen, a new banner displays with information on file transfer: 1: location of the uploaded file on 3: level of transferred data 2: location of the file on 6000A V2 4: bar graph of the trans- Fig. 68 Information on file transfer NOTE Only one file can be uploaded from PC to Platform at the same time.
Once transfer is completed, the banner disappears and the transferred file is underlined in blue on PC explorer. Working with Renaming file or directory files and Select a file/directory stored on the 6000A V2 Platform hard disk or USB key. directories on Click on 6000A V2...
Chapter 11 Smart Access Anywhere Connection information and settings Fig. 69 Session page This page gives information on connection «in real time». Modifying To modify the settings for connection to internet: connection Press Session menu key on left of the screen settings Disconnect from application pressing On the session screen (see...
Chapter 11 Smart Access Anywhere Connection information and settings To modify the current parameters, select Forced settings. The parameters for Port and HTTPS configurations turn automati- cally active. Modify, if necessary, the parameters for SSI tunnel port and/or Internet proxy. The Internet proxy configuration is available exclusively if the port selected is Alternative port (443) and if the HTTPS packing is selected.
Page 128
Chapter 11 Smart Access Anywhere Connection information and settings The screen displays, in two different tables: – the Upload and Download speed (in Kbyte/s) from Device to server. – the Latency between Device and server (in ms). Press to delete the current table, and retest connection if wished.
Page 129
WIFI Option Chapter 12 The WIFI application is available on option with the 6000A V2 Platform, and installed in factory, except if it has been ordered after the Platform delivery, in which case the customer must install himself the option (see “Installing the WIFI or Bluetooth option”...
Chapter 12 WIFI Option Configuration of the WIFI option Configuration of the WIFI option The WIFI option is delivered on a USB key installed into the Platform. A new icon displays on the upper banner once installation of the option is performed and Platform is re started. To display the Wifi configuration screen: Press H hard key to reach the Home page.
In the AutoConnect parameter, select if the connection to SSID selected must be done automatically (On) or not (Off). Connection to SSID Once configuration is valid, connect the 6000A V2 Platform to the Wire- less network: In the Setup screen, press Connect SSID menu key.
(Domain Name Server) IP address of the machine providing the IP address on the basis of the name – Domain name name of the local network to which the 6000A V2 Platform is connected. Dynamic in this mode, which requires a DHCP server, the...
Page 133
Dynamic in this mode, which requires a DHCP server, the 6000A V2 Platform requests an IP address from this server which will be allocated dynamically if dynamic host configuration is activated on the local network.
Figure 74 on page 112), enter the following address in the Internet Explorer window: http://10.33.16.229:5800 Press Enter to validate. The screen of the 6000A V2 Platform appears offset on your PC. Click to install TightVNC software on your PC (not mandatory) Fig. 76 VNC window “Virtual control buttons bar”...
On the PC, use an FTP client, and access to internal memory via an internet explorer (I.E, Mozilla Firefox...) or Windows Explorer. In the address bar, type the following address (10.33.16.229 being the IP address of the 6000A V2 Platform defined when the connection was configured): ftp://mts6000:acterna@10.33.16.229/disk/ This allows to access to internal memory.
Page 136
Chapter 12 WIFI Option Transferring files to/from a PC via WIFI User Manual 76100000200 Rev. 001...
Bluetooth option Chapter 13 The Bluetooth application is available on option with the 6000A V2 Plat- form, and installed in factory, except if it has been ordered after the Plat- form delivery, in which case the customer must install himself the option (see “Installing the WIFI or Bluetooth option”...
Chapter 13 Bluetooth option Setting up a Bluetooth connection Setting up a Bluetooth connection The Bluetooth option allows file transfers between the 6000A V2 Plat- form and another device On the Home page, press System Settings key Under I/O interfaces, select Bluetooth > Enable...
Page 139
If the desired device is not displayed on the screen, or if no devices are detected, press the Search Devices soft key. The 6000A V2 Platform is searching for the devices which could be used via Bluetooth with the equipment.
Page 140
The icon has a blue background when paired with a device versus no background when not paired You can now go to the file explorer and transfer files from the 6000A V2 Platform toward the bluetooth device and vice versa (see “Transferring...
Chapter 13 Bluetooth option Transferring files via Bluetooth Transferring files via Bluetooth Once the connection has been established with a bluetooth device: Press the key and then press the System Settings soft key. Use the down arrow or touchscreen to move to the I/O Inter- faces settings and then to File export.
(disk, usb key...). Transferring the Platform interface on a laptop PC via Bluetooth If the 6000A V2 Platform is paired with a laptop equipped with Bluetooth, the interface can be transferred on this PC in order to work on the unit from the laptop PC.
Page 143
Bluetooth on PC Click on View Unit button to remote the screen on PC. The current screen of the 6000A V2 Platform displays on a new window on the PC. In the small window next to VNC window (see...
Chapter 13 Bluetooth option Removing the Pairing At any time, the remote screen can be displayed back clicking on View Unit button. To close the application, click on File > Exit in the window. Removing the Pairing To remove the pairing between the two equipments, in the System Settings page, push the Bluetooth Pairing key In the screen displayed, push the Remove pairing key The icon on the upper banner of the screen becomes...
Technical specifications Chapter 14 This chapter contains the technical specifications of the 6000A V2 Plat- form. The topics discussed in this chapter are as follows: – “Display” on page 126 – “Memory” on page 126 – “Input/Output” on page 126 –...
Power supply Battery The instrument is supplied with one Lithium Ion battery: – a standard Lithium Ion battery with the 6000A V2 Platform and 6100 module box – a high power Lithium Ion battery with the 6000A V2 Platform and 6200 module box –...
6 impacts dropped from a height of 76 cm (1 impact on each of its 6 sides, with power off). Shocks The 6000A V2 Platform resists the following test: – 3 shocks per axis along each of the 3 axes, with power off.
(PSD) of 0.03 g²/Hz, 30 min per axis at vibration frequency range between 10-500 Hz. Flammability The housing of the 6000A V2 Platform (in ABS, type V0) does not prop- agate fire. Characteristics of the options Power meter Specifications given for 25°C, after 20 minutes stabilization time and after...
Chapter 14 Technical specifications Characteristics of the options – Measurement range:+5 to -50 dBm (-45 dBm from 800 to 1250 nm) – Linearity within the measurement range: ± 0.2 dB – Wavelength: 650 nm – Length of fiber: up to 5 km –...
This chapter shows the references of the options and accessories of the 6000A V2 Platform. The topics discussed in this chapter are as follows: – “References of options for the 6000A V2 Platform mainframe” on page 132 – “References of scopes and associated accessories” on page 134 –...
References of options for the 6000A V2 Platform mainframe References of options for the 6000A V2 Platform mainframe Platforms References 6000A V2 Platform with high visibility colour touchscreen EM6000AV2M /ETB6000AV2M (US) 6000A V2 Platform with colour touchscreen EM6000AV2S /ETB6000AV2S (US) Module carriers...
Page 153
Built-in Bluetooth option for 6000A V2 Platform E60V2BLUE Smart Access Anywhere (Software license) References Smart Access Anywhere for 6000A V2 Platform - L1: Remote coach- ing and file transfer for T-BERD/MTS-6000 using Ethernet or WIFI SAA-6KAV2-L1 hotspot connection Smart Access Anywhere for 6000A Platform - L2: Remote coaching...
U25MA & U12M) Carrying case for fiber microscope and accessories EOCIS-SC1 References of accessories Soft and hard carrying cases Reference Wrap around carrying case for 6000A V2 Platform ESCASE6KV2 Wrap around Soft Case E40SCASE1 User manual for 6000A V2 Platform platform Reference...
Page 155
Chapter 15 Options and accessories References of accessories NOTE The User Manuals for MTS/T-BERD 6000A V2 (Platform & Modules) are available in pdf format, into the unit. The printed versions of the manuals are available on option, in French, English and German.
Page 156
Chapter 15 Options and accessories References of accessories User Manual 76100000200 Rev. 001...
Page 157
Maintenance and Chapter 16 Troubleshooting This chapter describes how to maintain your unit and identify and correct problems related to the 6000A V2 Platform. The topics discussed in this chapter are as follows: – “Maintenance procedure” on page 138 –...
Maintenance work on this instrument must only be undertaken by qualified personnel using suitable equipment. In most cases, it is advisable to contact the nearest Viavi Service Centre, which will undertake the appropriate troubleshooting and repair work. The performance and technical complexity of the 6000A V2 Platform...
Installing a module Installing the If some options have been ordered after the delivery of the T/BERD-MTS 6000A V2, they have to be mounted by the customer. options Installing a Hard If the hard disk is ordered after the delivery of the Platform, it has to be inserted into the equipment by the customer.
Set back the module pack onto the base pack If necessary plug the equipment to charge the battery Switch on the 6000A V2 Platform. Press F hard key to display the explorer, with the new drive «hard disk» on the left of the screen If the hard disk has not been detected, turn off the instrument and check the installation of the hard disk into the base.
WIFI / Bluetooth option installation Set back the cover, then the module pack onto the base pack If necessary plug the equipment to charge the battery Switch on the 6000A V2 Platform. Press H hard key to display the Home page and press System Settings menu key to display the WIFI/Bluetooth parameters..
The software version information – The product contents: base, optical options, battery type, module installed and date of calibration for options concerned. The options set into the 6000A V2 Platform are marked with a green tick. User Manual 76100000200 Rev. 001...
6000A V2 Platform To display the list of documents available for 6000A V2 Platform use: documentation Validate the Help icon on the Home page. In the new page, click one link to display the corresponding docu- ment: User manual, Getting Started Manual, Quick Card...
Do not interrupt the installation process, as this could damage the instrument. To avoid any interruption of the installation procedure, the 6000A V2 Platform must be operating on the mains: if the procedure is started while operating on battery, a message indicates that the instrument must be connected to the mains.
The update can be performed directly onto the equipment, using the Viavi Server Viavi server. Connect the 6000A V2 Platform to a PC via an Ethernet link. On the Home page, press System Settings key to open the System Settings page.
PC server. The update can be performed directly onto the equipment, using an http address. Connect the 6000A V2 Platform to a PC via an Ethernet link. On the Home page, press System Settings key to open the System Settings page.
Chapter 16 Maintenance and Troubleshooting Maintenance procedure The list of the software versions available on the PC is displayed next to the versions installed on the 6000A V2 Platform (see Figure 94 on page 146). Installation from a You must be equipped with a USB memory stick with a minimum USB memory stick capacity of 128 Mo.
USB. The message Are you sure? is displayed Click on Confirm. The list of the software versions available on the USB stick is displayed next to the versions installed on the 6000A V2 Platform (see Figure 94 on page 146).
Chapter 16 Maintenance and Troubleshooting Maintenance procedure Check the Address Type is set to Viavi Server. Define the parameter Check new release to Enable. If the parameter is set to Enable, a message displays, at any time, when one update is available on server.
The Testing indicator will be lit in red during upgrade. Do not push any key or remove the USB memory stick until the lit turns off. Once the upgrade is completed, the 6000A V2 Platform will auto- matically turrs on and display the Home page. Installing The menu key Install Option allows to import the licence to get a soft- ware option.
Chapter 16 Maintenance and Troubleshooting Maintenance procedure Enter the challenge code of the option, set at the bottom of the file (see Figure 97 on page 150), Fig. 98 Enter the Licence code The license file can be opened via a word processing software such as Word...
Home page, press Expert Tools > Instrument Lock Out Platform Confirm the 6000A V2 Platform locking by clicking on Confirm (or use the Cancel key to cancel the process). The numeric keypad is displayed Enter the password to lock the instrument: 42000.
The returned instrument will then be repaired and calibrated. Guarantee Any repair operation supervening within the guarantee period of the instrument will be carried out at the expense of Viavi. However, for any conditions sub-assembly upon which work has been carried out otherwise than by Viavi Service Centers, the cost of a replacement sub-assembly will be invoiced.
Chapter 16 Maintenance and Troubleshooting Recycling Information Recycling Information Viavi recommends that customers dispose of their instruments and peripherals in an environmentally sound manner. Potential methods include reuse of parts or whole products and recycling of products components, and/or materials.
Formatting the If the USB icon is displayed on the upper banner of the screen, when a USB memory stick is connected to the 6000A V2 Platform, this USB memory may means the memory stick must be formatted. stick onto the...
Removing the To access the battery of the 6000A V2 Platform, proceed as follows damaged battery Switch off the 6000A V2 Platform and disconnect the mains supply.
Chapter 16 Maintenance and Troubleshooting Troubleshooting Slacken the two screws located at the bottom of the instrument using a coin, and unscrew them Remove the cover of the battery pack. The battery can then be removed, taking care not to damage the connectors into which it is plugged.
Viavi for repair or replacement shall be borne by customer until delivery to Viavi. Upon delivery of such product, Viavi shall assume the risk of loss or damage until that time that the product being repaired or replaced is returned and delivered to customer.
Chapter 16 Maintenance and Troubleshooting General information on warranty costs for equipment or software shipped to Viavi for repair or replace- ment. Viavi shall pay all transportation costs associated with returning repaired or replaced product to customer. Warranty For hardware and/or services furnished by Viavi, the foregoing warran- ties are in lieu of all other warrantees and conditions, express or implied.
Page 180
Chapter 16 Maintenance and Troubleshooting General information on warranty User Manual 76100000200 Rev. 001...
Calibration Recommended Appendix A The following appendix provides recommended calibration period for the MTS/T-BERD 6000 and MTS/T-BERD 6000A. User Manual 76100000200 Rev. 001...
Appendix A Calibration Recommended Recommended Calibration Period Recommended Calibration Period Mainframe equipped with Power Meter option 12 months Mainframe equipped with Laser Source option 12 months Mainframe used with Reflectometer module 12 months Mainframe used with Fiber Characterization 12 months module (CD / PMD / AP) Mainframe used with MSAM module...
Index About page Calculator AC Adaptor CD OTDR file specifications Cladding Accessories Cleaning AP file connectors plates, housings and screen Application calculator Connectors Assembling the component parts Connectors & adapters references Attenuation accuracy of measurement Core CSV file Battery specifications Datalink Battery charger Delete disk...
Page 184
Index keyboard and platform Ethernet mode JPG,JPEG file Ethernet IPv6 License Ferrule enter manually import from USB File merge License file storage media transfer connection for process Memory File explorer capacity File Transfer Module carrier Bluetooth E-mail MSOR file Smart Access Anywhere WIFI Front Panel ODM file...
Page 185
WIFI connection Report WIFI connection & 3G smart- result phone Soft and hard cases references Software update via Internet Scope via USB about page via Viavi Server auto center Specifications capture button cladding Storage media comment abbreviations core epoxy feature ferrule...
Page 186
Index TXT file VNC (Talkset) connection Web Browser disconnection access upgrade via bookmarks User manual navigation references pdf document quit WIFI 802.11 802.11 IPv6 configuration connection file transfer emission of light interface transfer function reference reference specifications Virtual control buttons bar Virtual control buttons bar, XML file User Manual...
Page 188