Viavi OneExpert ONX CATV 620 Quick Start Manual

Viavi OneExpert ONX CATV 620 Quick Start Manual

Hide thumbs Also See for OneExpert ONX CATV 620:
Table of Contents

Advertisement

OneExpert
ONX CATV 620
Extended Quick Start Guide v7
August 2017

Advertisement

Table of Contents
loading

Summary of Contents for Viavi OneExpert ONX CATV 620

  • Page 1 OneExpert ONX CATV 620 Extended Quick Start Guide v7 August 2017...
  • Page 2 ONX CATV - Interfaces and Controls ONX CATV - SW Upgrade and Data Synchronization ONX CATV – Engineering Mode ONX CATV - Ethernet Testing ONX CATV – CATV Testing ONX CATV - StrataSync © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 3 ONX CATV - Overview...
  • Page 4 ONX Controls keys Network Indicator LEDs High Sensitivity Touch Screen Shortcut Buttons Short Cut Hard keys – Functions keys Navigation Directional Buttons Back, Home Screen, and Utility Buttons Power On/Off Button © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 5 Port 1 – RF US/DS Analysis Connect to DOCSIS, upstream from house for Ingress Scan D-Ring Dual 10/100/1000 RJ45 Ports Dual USB 2.0 Ports Battery Charger Port (under flap) © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 6 The unit can continue to run, and no user intervention necessary. ✓ Solid amber indicates that the battery is charging. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 7 10%. ✓ Solid amber application. indicates that the battery is getting low, and the charge is between 10% and 30%. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 8 A long push on TRAY key will automatically start a screen capture. It is useful when a short Tray key push doesn’t open the Tray menu (when for example a function key menu is open) © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 9: User Interface

    ✓ You can create up to four shortcuts. ✓ To remove the shortcut, drag it off the shortcut bar. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 10 Shortcuts are located across the bottom and can be customized by selecting an icon and dragging it to the shortcut bar © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 11: System Settings

    ✓turn on Remote Operation (via VNC Viewer), ✓change power and screen settings, ✓view Hardware and Software versions, ✓view Options purchased with ONX 620 meter and ✓ complete USB Software updates © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 12 ✓The ONX CATV support interoperability Via IP connection such as Tight VNC or VNC Viewer ✓Under Systems Settings is Remote Operation allowing IP connection and control and also remote file browsing over HTTP © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 13 Troubleshoot faster & more efficiently ONX-620 • Fault & test point often at different locations • Integrate with StrataSync • Technician Aids On App • Tutorials, videos, manuals • Accessory guide © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 14 If the applicable setting is enabled, Quick Check CW channels are added to the channel plan build process. This should assist with discovery of any CW channels that are being missed or misidentified. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 15 ✓ CATV Settings provides the option for default work order ID to be the last selected work order instead of “Work Order” with date/time stamp. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 16 ONX Calibration Certificate (StrataSync) © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 17 ONX CATV - SW Upgrade and Data Synchronization...
  • Page 18 ONX Software / Firmware Upgrades • Software (SW) and Firmware (FW) releases are the best way to ensure your VIAVI OneExpert ONX is functioning at its best. • VIAVI delivers SW and FW easily via StrataSync USB Stick • All ONX units should be upgraded to the latest production software release – available through StrataSync (or your Viavi representative) •...
  • Page 19 USB thumb drive. Press Cancel once the download has completed and you have placed the file on the USB thumb drive. Note: Firmware must be downloaded from StrataSync first © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 20 Press Update to confirm and start the upgrade. The meter will power off when the update is complete. Note: Make sure you do not have an Ethernet cable plugged in when upgrading by USB © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 21 From the ONX home screen navigate to active internet connection (Cable System Menu and select Network - Verify the Modem or router/gateway) to Port ONX has a valid IP address* 1 on the ONX © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 22 Connect with WiFi from an active From the ONX home screen navigate to internet connection (Cable Modem System Network / WiFi- Verify the ONX has a or router/gateway) valid IP address © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 23 Sync via RF Port 1 please use the “Connection” app in the CATV section at the top of the Home screen to establish a live connection with the CMTS prior to syncing to StataSync. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 24 10-15 minutes based on the size of the update file and connection speed The ONX will require that it is plugged into AC power or above 50% battery life prior to updating © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 25 Press the Back Select Ethernet button and Power Cycle the Meter *When the meter returns to the Home screen start from Step 1 at the beginning of this document © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 26 System Settings − Remote Operation of ONX © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 27 ONX CATV - Engineering Mode...
  • Page 28 5. Release the Tray key 6. Go in CATV setting and select Engineering Utilities 7. Select “Use Simulator” 8. Reboot the unit IMPORT: NEVER UPGRADE A ONX CATV in Demo Mode ! © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 29 6. Go in CATV setting and select Engineering Utilities 7. Select “Built-in Self Test” and Start BIST : 8. Go to File Browser and copy the custBist .zip file to a plugged USB memory stick : © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 30 ONX CATV - Ethernet Testing...
  • Page 31 Ethernet – Tests and Settings From Home Screen, select Ethernet ✓ Once Network Up is indicated with green, select Test and Settings © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 32 • CATV Ethernet’s throughput IP Address/URL is configured in the mode under Settings. • Default value are for booth Downstream/Upstream the same: http://CATVSpeedTest.viavisolutions.com/bigfile.zip • If the upstream url change, the file name need to be the same: bigfile.zip © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 33 TrueSpeed Setup • TrueSpeed can be found under Tests and Settings and REQUIRES TrueSpeed VNF Server IP Address © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 34 • Stop Test and choose Server Settings on the bottom and enter the Server IP address and then resume. (Only applicable for first test setup) • Fallback Server is for second TrueSpeed VNF and can help alleviate queue © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 35 TrueSpeed Results • After test completes, Results are displayed as either the Speedometer or an a simple list © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 36 ONX CATV - Testing - Quick check - Spectrum - Channel Check - DOCSIS Check - One Check - Ingress Scan...
  • Page 37 ✓ If Work Order ID is not entered before a test is started in a new location (different channel plan area), the unit will display error below. Press Clear Session to ignore and run test. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 38 HSD services number of manually added channels ✓ Troubleshoot and analyze Downstream and and quickly determine if signal is Upstream DOCSIS carriers including OFDM present and channel bonding © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 39 ONX through StrataSync determines a you want to capture a Important! Pass or Fail, at each test location specific result prior to Session Expert determines downstream Retesting or upstream issue. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 40 ONX CATV – Quick Check...
  • Page 41 Start ✓Navigate the Results Screen (shown to the right) channels and quickly determine if signal is present using touchscreen or Directional Buttons ✓ Add/remove frequency and type of carrier © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 42 QuickCheck Results © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 43 ONX CATV - Spectrum...
  • Page 44 Spectrum Setup ✓Enter Work Order ID and choose proper demarcation point ✓Navigate the Results Screen (shown to the right) using touchscreen or Directional Buttons © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 45 ✓ Choose Display to change to landscape view or manually change graph division size, span and toggle Live/Max and Min traces ✓ Choose Settings to change RBW and AGC settings © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 46 Spectrum Results • Drag or use Directional buttons to move marker • Double tap on the marker to display Delta between second marker which will appear © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 47 ONX CATV – Channel Check...
  • Page 48 Navigate the Results Screen (shown to the • Analyze OFDM carriers including analysis of right) using touchscreen or Directional multiple DS profiles Buttons • Use ChannelCheck to quickly check levels and signal performance © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 49 Measurements Find channel Note: Find Channel should be entered as “4” and not “04” Note: All results are live updated every time channel under test is changed © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 50 Channel Check Results Level Over Time BER, Pre and Post, over Time MER Over Time DQI Over Time © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 51 Channel Check Results ICFR Smartscan Graph View of Tilt Favorites Table View of Favorites © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 52 Channel Check Results Favorite selection in Channel View Table View of Favorites Constellation © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 53 Familiar “swipe” navigation provides access to individual DQI over time VIAVI Exclusive Spectrum view channel details identifies with embedded Ingress Under the Carrier trace intermittent issues © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 54 TAP, GB and CPE ICFR highlights roll-off and suck-out problems within a downstream carrier Favorites view provides technicians with a quick mini-scan of critical carriers © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 55 ONX CATV – DOCSIS Check...
  • Page 56 Navigate the Results Screen (shown to the to focus on HSD services right) using touchscreen or Directional • Troubleshoot and analyze Downstream and Buttons Upstream DOCSIS carriers including OFDM and channel bonding © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 57 Dashboard Level Over Time Downstream bonded DOCSIS MER Over Time Channels Adjacent Channels channel under test Note: All results are live updated every time channel under test is changed © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 58 Upstream bonded DOCSIS Carriers DQI Over Time Transmit Over Time (based on Upstream carrier under test) Note: All results are live updated every time channel under test is changed © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 59 Carriers Upstream EQ ✓ Cable Modem Analysis with ✓ CPE Footage to ✓ Servers Impedance Mismatch Note: All results are live updated every time channel under test is changed © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 60 Test over ✓ Packet Loss DOCSIS ✓ Max Round Trip delay ✓ Max jitter Note: Throughput and Packet Quality requires config in StrataSync, Refer to Administrator Settings section for details © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 61 ONX CATV - OneCheck...
  • Page 62 ✓Navigate the Results Screen (shown to the utilizing both ports on the ONX 620 in under 2 mins right) using touchscreen or Directional Buttons © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 63 After test completion, push OK key to get more details Even if Settings are setup to 1.0E-8 the DOCSIS channels will display 1.0E-9 BER DOCSIS test duration allows to get better BER resolution. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 64 OneCheck Results Upstream Ingress Full Scan DOCSIS Test Ingress Details Session Expert Note: ✓ Double tap on each section of the OneCheck dashboard for Details © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 65 Notes: ✓ Double tap on each section of the OneCheck dashboard for Details ✓ Troubleshoot in ChannelCheck Button available for live measurements ✓ Off-Air Ingress configuration available through StrataSync © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 66 Button channel table available for live measurements Notes: ✓ Double tap on each section of the OneCheck dashboard for Details ✓ Troubleshoot in DOCSISCheck Button available for live measurements © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 67 ✓ Upstream and Downstream analysis is compared against Limit Plan (configurable in StrataSync) ✓ Based on results, Session Expert displays where it believes the network issues are located © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 68 ✓ Session awareness (tests within the current Job) uses data at the demarcation points to suggest next actions ✓ Side by side comparison helps technicians prove they have fixed the problems © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 69 CPE speeds wide best practices up technician analysis time and reduces call backs Overlayed comparison of Ingress Scans between the TAP and GB help highlight where ingress is getting in © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 70 OneExpert CATV – OneCheck Session Expert Details Side by side comparisons of measurements between TAP, GB, and © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 71 TAP, GB or SmartScan simplifies system analysis by taking System summary out the effects of tilt view and different carrier types at TAP, GB and CPE © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 72 OneCheck Downstream Details System wide view of performance Identification of Off-Air interferers that are infiltrating the downstream (user definable frequencies – configuration by StrataSync) © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 73 TX level and ICFR value Packet Quality identifies if packets are being lost over the RF portion of the data layer which may be caused by a physical layer problem. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 74 ONX DOCSIS 3.1 Measurements...
  • Page 75 Testing OFDM © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 76 ✓ OFDM demodulation with D3.1 Profile Analysis ✓ Full DOCSIS service testing including 32 Bonded + D3.1 OFDM carrier ✓ Upstream DOCSIS 3.1 OFDM-A capable © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 77 VoIP! ✓ Correctable CWEs are an early warning that the uncorrectable threshold may be near! (think pre-FEC BER) THINGS TO CHECK: To make sure there are no uncorrectable CWE © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 78 CRITICAL OFDM signal decoding information THINGS TO CHECK: Level: >-15 dBmV (6 MHz) MER: >15 dB (min) Lock status: locked Uncorrectable CWE: none Other info: PLC center frequency © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 79 CM's ability to correctly receive NCP or CWs. THINGS TO CHECK: Lock status: locked NCP’s start at HIGH Codewords start at Uncorrectable CWE: none LOW frequencies and frequencies and populate UP down populate © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 80 ✓ If profile A isn’t locked or has uncorrectable CWE, a modem may roll back and use only SC QAMs in 3.0 mode. THINGS TO CHECK: Lock status: locked Uncorrectable CWE: none © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 81 41.0 2048 37.0 Avg MER, variable: >36 dB recommended 1024 34.0 MER at 2 percentile: >35 dB recommended 30.5 27.0 MER standard deviation: <2 dB recommended 24.0 21.0 15.0 © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 82 ✓ Profile changes highlight drop or home wiring problems: Ground Block Outlet/CPE Uncorrectable Uncorrectable Uncorrectable Profile Profile Profile Locked? Locked? Locked Profile A Profile B Profile C Profile D © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 83  1024 34.0 but LDPC is correcting them all! 30.5 27.0  This makes sense, 1024 QAM level 24.0 21.0 should be ≥12dBmV and MER > 34 dB 15.0 © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 84 256 QAM or lower will work. Level variation within In-Channel the OFDM channel band Response identifies provides insight into roll-off and excessive frequency-response ripple related issues. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 85 ✓ Consumer-grade PC HW limitations can prevent testing up to 1 Gbps.  Testing both DOCSIS and Ethernet layer to 1 Gbps helps distinguish between service problems and equipment problems. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 86 Example: Single 6MHz channel power = 5 dBmV   Total Power(96MHz channel) = 5dBmV + 10log (16) = 5 + 12.04 = 17.04dBmV This is what some spectrum analyzers (like R&S FSW) show © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 87 ✓ Do not use the total OFDM power to adjust CMTS output for example, all at power: this would be like using total integrated power of 32 10dBmV DOCSIS QAM carriers to set level. © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 88 ONX CATV - Ingress Scan...
  • Page 89 ✓ Enter Work Order ID and ensure Port 2 is connected ✓ Navigate the Results Screen (shown to the right) using touchscreen or Directional Buttons ✓ Landscape view available as well © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 90 ✓ Move marker with touch or Directional Buttons Use Touchscreen or ✓ Touch once to open or Directional Buttons to close second marker with navigate delta information Zoom Marker © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 91 ONX CATV - WiFi Testing - WiFi scan - ONX as Access Point - Testing with WiFi advisor...
  • Page 92 Buttons ✓ Choose bottom buttons to see AP List, Channel Graph, or Time Graph ✓ When using the AP List screen, select APs to graph, or choose Graph All © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 93 ✓ When using the AP List screen, select APs to graph, or choose Graph All ✓ Channel Graph allows 2.4Ghz or 5Ghz views ✓ Time Graph tracks received signal (signal level) over time with ability to select specific AP or view multiple © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 94 WiFi Advisor on the ONX CATV • ONX CATV is interoperable with the Viavi WiFi Advisor companion probe • iPad or Android Tablet is optional, but allows use of the Two-Ended Site Assessment Feature © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 95 Management to add WiFi pairs, and it prompts the Blur button down and Advisor Units user for label, it is placing WiFi Advisor unit displayed into pairing mode © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 96 WiFi Advisor Setup – Test Options WiFi Link Under Test NOTE: ✓ Site Assessment Assistant requires use of iPad or Android tablet and is not covered in this document © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 97 WiFi Advisor Results ✓ BSSID View shows list of Aps, choosing one shows © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 98 WiFi Advisor Results ✓ Scrolling down shows more info; Noise, Channel Score, Best Channels © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 99 WiFi Advisor Results ✓ Spectral Button can be toggled to include 2.4G and 5G spectrum, as well as 20/40/80 Channel width © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 100 ONX CATV - Fiber Testing - P5000i Probe Microscope - MP60, MP80 power meters...
  • Page 101 Fiber Inspection ✓ P5000i Automatic fiber scope support ✓ Auto Centering ✓ Automated testing ✓ Simple pass/fail ✓ Power Meter ✓ USB power meter support ✓ MP-60 & MP-80 © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 102 After plugging in patch cord or inserted probe into bulkhead, fiber end face will appear and can be focused or auto centered using controls on P5000i. • Autotest can be conducted and results saved from results screen © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 103 StrataSync – Cloud-Based Meter Management • All high-level features for StrataSync are accessible from the main landing page • Asset and Test Data information is displayed and details are available © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 104 To access Configuration Templates © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 105 In the Template screen, click on one of the selections in the “Global Archives” bubble on the left of the screen ▪ Users can create Limit Plans, DOCSIS Service Plans, Off Air Ingress Plans, and default Measurement Settings © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 106 Limit Plan Window • Choose from existing Limit Sets or select New Limit Plan © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 107 Limit Plan Creation – Name New Limit Plan ▪ Enter Limit Plan name and Description and select Create © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 108 Warning = Pass but No Fail – rather the measurement is highlighted to bring attention to it if the result exceeds the limit • None = Test result is shown but no Pass or Fail criteria is applied to the result © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 109 Limit Plans can be deployed to Meter or Copied to Templates • Check the box of the limit plan to be deployed, right click or select Actions • Click “Deploy” or Copy to Template © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 110 Deployment – Meter Selection ▪ Check the boxes next to one or more OneExpert and then select Next in bottom right corner of the screen © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 111 Access or Create a New DOCSIS Service Plan • In the Template screen, click on one of the selections in the “Global Archives” bubble on the left of the screen • Select DOCSIS Service Plans © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 112 DOCSIS Service Plan Window • Choose from existing Limit Sets or select New Limit Plan © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 113 DOCSIS Service Plan – Name New DOCSIS Service Plan • Enter DOCSIS Service Plan name and Description and select Create © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 114 • VoIPCheck Server – If a VoIPCheck reflection server is available this can be entered into the VoIPCheck Server field (Note: VoIPCheck is not yet implemented on ONX) © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 115 Type, like in the Limit Plans, determine how the test result is presented on the ONX • The VoIPCheck Limits are also configurable (Note: ONX does not currently perform VoIPCheck testing, these limits can be set for future use) © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 116 DOCSIS Service Plans can be deployed to Meter or Copied to Templates • Check the box of the DOCSIS Service Plan to be deployed, right click or select Actions • Click “Deploy” or Copy to Template © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 117 Deployment – Meter Selection ▪ Check the boxes next to one or more OneExpert and then select Next in bottom right corner of the screen © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 118 Off-Air Ingress Plan Window • Choose from existing Off-Air Ingress Plan or select New Off-Air Ingress Plan © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 119 Enter the Label, Start, Stop, Limit value, and Limit Type for each Ingress band desired Use the green + or red – to add or delete Off-Air Ingress bands ▪ Press the SAVE button to save the Off-Air Ingress Plan configuration © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 120 Off-Air Ingress Plan can be deployed to Meter or Copied to Templates • Check the box of the Off-Air Ingress Plan to be deployed, right click or select Actions • Click “Deploy” or Copy to Template © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 121 Deployment – Meter Selection ▪ Check the boxes next to one or more OneExpert and then select Next in bottom right corner of the screen © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 122 Access or Create a New Measurement Settings • Access or Create a New Measurement Settings © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 123 Measurement Settings Window • Choose from existing Measurement Settings or select New Measurement Settings © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 124 Measurement Settings – Name New Measurement Settings • Enter Measurement Settings name and Description and select Create © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 125 If disabled then the ONX will not perform IP service testing during a OneCheck test • Note: To enable DOCSIS Service Tests the DOCSIS Test must be enabled as well © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 126 Measurement Settings can be deployed to Meter or Copied to Templates • Check the box of the Measurement Settings to be deployed, right click or select Actions • Click “Deploy” or Copy to Template © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 127 Deployment – Meter Selection ▪ Check the boxes next to one or more OneExpert and then select Next in bottom right corner of the screen © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 128 ONX CATV - StrataSync - Test Results...
  • Page 129 StrataSync − ONX CATV test result © 2017 Viavi Solutions, Inc. | Viavi Confidential and Proprietary Information...
  • Page 130 www.viavisolutions.com...

Table of Contents