Chapter 16 Fiber Characterization
Fiber Characterization Test Sequence in Manual mode
Configuring the "Results" Summary table
This summary table enables to review selected values at the end of the test
sequence. A Pass/Fail status is associated to the table.
1
Press softkey Select Results to Display to access the list.
2
Highlight one parameter in the column Available results.
3
Press the soft key Add Result in order to select the parameter and
see it in the column Results to display.
4
Repeat steps 1 to 3 until you have selected all the parameters.
Maximum 7.
5
Press the soft key Validate in order to acknowledge the selection.
Figure 216 Summary table contents
6
Press Exit to return to Fiber Characterization screen.
490
Set the Direction of the measurement between A->B and B->A
(Origin and End).
If the Origin fiber number or cable Id is different from the far end,
check mark Different extremities in order to have access to the
local and distant information using the Settings: Local / Distant
soft key.
User Manual
78000010220 Rev. 023