[:LEVel] <value>, (@chanlist)
            :RANGe <value>, (@chanlist)
            :SENSe
                  :SOURce INTernal|EXTernal, (@chanlist)
            :SLEW
[:IMMediate] <value>|INFinity, (@chanlist)
                  :MAXimum 0|OFF|1|ON, (@chanlist)
STATus
      :OPERation
[:EVENt]? (@chanlist)
            :CONDition? (@chanlist)
            :ENABle <value>, (@chanlist)
            :NTRansiton <value>, (@chanlist)
            :PTRansiton <value>, (@chanlist)
      :PRESet
      :QUEStionable
[:EVENt]? (@chanlist)
            :CONDition? (@chanlist)
            :ENABle <value>, (@chanlist)
            :NTRansiton <value>, (@chanlist)
            :PTRansiton <value>, (@chanlist)
SYSTem
      :CHANnel
[:COUNt]?
            :MODel? (@chanlist)
            :OPTion? (@chanlist)
            :SERial? (@chanlist)
      :COMMunicate
            :LAN|TCPip:CONTrol?
            :RLSTate LOCal|REMote|RWLock
      :DATE <yyyy>,<mm>,<dd>
      :ERRor?
      :GROup
            :CATalog?
            :DEFine (@chanlist)
            :DELete (@channel)
                  :ALL
      :PASSword
            :FPANel
                  :RESet
      :PERSona
Keysight N6705C Operating and Service Guide
Sets the negative remote OV protection level. (only on N6784A)
Sets the output voltage range.
Sets the state of the output remote sense relays.
Sets the voltage slew rate.
Enables/disables the maximum slew rate override.
Queries the operation event register.
Queries the operation condition register.
Sets the operation enable register.
Sets the negative transition filter.
Sets the positive transition filter.
Presets all Enable, PTR, and NTR registers.
Queries the questionable event register.
Queries the questionable condition register.
Sets the questionable enable register.
Sets the negative transition filter.
Sets the positive transition filter.
Returns the number of output channels in a mainframe.
Returns the model number of the selected channel.
Returns the option installed in the selected channel.
Returns the serial number of the selected channel.
Returns the initial socket control connection port number.
Configures the remote/local state of the instrument.
Sets the date of the system clock.
Reads and clears one error from the error queue.
(GROup commands do NOT apply to models N678xA SMU)
Returns the groups that have been defined.
Group multiple channels to create a single channel.
Remove the specified channel from the group.
Ungroups all channels.
Resets the front panel lockout password to zero.