Keysight N6705C Operating And Service Manual page 32

Dc power analyzer
Table of Contents

Advertisement

1 Quick Reference
                  :CURRent 0|OFF|1|ON, (@chanlist)
      :SWEep
            :OFFSet
                  :POINts <value>, (@chanlist)
            :POINts <value>, (@chanlist)
            :TINTerval <value>, (@chanlist)
                  :RESolution RES20|RES40
      :VOLTage
[:DC]
                  :RANGe
[:UPPer] <value>, (@chanlist)
                        :AUTO 0|OFF|1|ON, (@chanlist)
      :WINDow
[:TYPE] HANNing|RECTangular, (@chanlist) Selects the measurement window.
[SOURce:]
ARB
            :COUNt?
            :CURRent | :VOLTage
                  :CDWell
[:LEVel] <value>, {<value>}, (@chanlist)
                        :DWELl <value>, (@chanlist)
                        :POINts? (@chanlist)
                  :CONVert (@chanlist)
                  :EXPonential
                        :END
[:LEVel] <value>, (@chanlist)
                        :STARt
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
                        :TCONstant <value>, (@chanlist)
                        :TIMe <value>, (@chanlist)
                  :PULSe
                        :END
                              :TIMe <value>, (@chanlist)
                        :STARt
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
                        :TOP
[:LEVel] <value>, (@chanlist)
                              :TIMe <value>, (@chanlist)
                  :RAMP
32
Enables/disables current histogram.
Defines the offset in a data sweep for triggered measurements.
Defines the number of points in a measurement.
Defines the time period between measurement samples.
Sets the measurement resolution.
Selects a DC voltage measurement range.
Enables/disables seamless measurement autoranging. (N6781A, N6782A)
Sets the ARB repeat count.
Specifies current or voltage Arbs
Sets the list of the constant dwell Arb
Sets the dwell time for the constant dwell Arb
Returns the number of constant-dwell Arb points
Converts the selected Arb to a user-defined list
Sets the end level of the exponential Arb
Sets the initial level of the exponential Arb
Sets the length of the start time or delay
Sets the time constant of the exponential Arb
Sets the time of the exponential Arb
Sets the length of the end time
Sets the initial level of the pulse
Sets the length of the start time or delay
Sets the top level of the pulse
Sets the length of the pulse
Keysight N6705C Operating and Service Guide