Keysight N6705C Operating And Service Manual page 34

Dc power analyzer
Table of Contents

Advertisement

1 Quick Reference
                              :POINts? (@chanlist)
            :FUNCtion <function>, (@chanlist)
                  :SHAPe <function>, (@chanlist)
                  :TYPE CURRent|VOLTage, (@chanlist)
            :SEQuence
                  :COUNt <value>|INFinity, (@chanlist)
                  :LENGth? (@chanlist)
                  :QUALity? (@chanlist)
                  :RESet (@chanlist)
                  :STEP
                        :COUNt <value>|INFinity, <step#> (@chanlist)
                        :CURRent <function>, <step#> (@chanlist)
                        :FUNCtion
                              :SHAPe <function>, <step#>, (@chanlist)
                        :PACing DWELl|TRIGger, <step#> (@chanlist)
                        :VOLTage <function>, <step#> (@chanlist)
                  :TERMinate
                        :LAST 0|OFF|1|ON, (@chanlist)
            :TERMinate
                  :LAST 0|OFF|1|ON, (@chanlist)
[SOURce:]
CURRent
[:LEVel]
[:IMMediate]
[:AMPLitude] <value>, (@chanlist)
                  :TRIGgered
[:AMPLitude] <value>, (@chanlist)
            :LIMit
[:POSitive]
[:IMMediate]
[:AMPLitude] <value>, (@chanlist)
                  :COUPle 0|OFF|1|ON, (@chanlist)
                  :NEGative
[:IMMediate]
[:AMPLitude] <value>, (@chanlist)
            :MODE FIXed|STEP|LIST|ARB, (@chanlist)
            :PROTection
                  :DELay
[:TIME] <value>, (@chanlist)
                        :STARt SCHange|CCTRans, (@chanlist)
                  :STATe 0|OFF|1|ON, (@chanlist)
            :RANGe <value>, (@chanlist)
34
Returns the number of points
Selects the Arb function (for backward compatibility)
Selects the Arb function (replaces ARB:FUNCtion)
Selects the Arb type (replaces ARB:FUNCtion)
Sets the number of times the sequence is repeated
Returns the number of steps in the sequence
Returns the quality of the waveforms in the sequence
Resets the sequence to its power-on default setting
Sets the number of times the sequence step is repeated
Programs the waveform steps within a current sequence
Creates a new sequence step
Specifies the type of pacing for the step
Programs the waveform steps within a voltage sequence
Sets the sequence termination mode
Sets the Arb termination mode
Sets the output current.
Sets the triggered output current
Sets the positive current limit. (only on N678xA SMU, N6783A)
Sets the current limit tracking state. (only on N678xA SMU)
Sets the negative current limit. (only on N678xA SMU, N6783A-BAT)
Sets the transient mode.
Sets the over-current protection delay.
Specifies what starts the over-current protection delay timer.
Enables/disables the over-current protection.
Sets the output current range.
Keysight N6705C Operating and Service Guide