7 SCPI Programming Reference
Parameter
(none)
Step 0 - 99, *RST 0
Returns the number of current BOST points: ARB:CURR:UDEF:BOST:POIN? (@1)
Returns the number of voltage BOST points: ARB:VOLT:UDEF:BOST:POIN? (@1)
Returns the number of BOST points for step 0: ARB:SEQ:STEP:CURR:UDEF:BOST:POIN? 0,(@1)
[SOURce:]ARB:CURRent:UDEFined:DWELl <
[SOURce:]ARB:CURRent:UDEFined:DWELl? (@<chanlist>)
[SOURce:]ARB:VOLTage:UDEFined:DWELl <
[SOURce:]ARB:VOLTage:UDEFined:DWELl? (@<chanlist>)
Specifies the dwell time for each user-defined current Arb point. A comma-delimited list of up to 511
points may be programmed. Dwell time is the time that the output will remain at a specific point. Dwell
times can be programmed from 0 through 262.144 seconds with the resolution shown in the table
below:
[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:DWELl <
[SOURce:]ARB:SEQuence:STEP:CURRent:UDEFined:DWELl? <
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:DWELl <
[SOURce:]ARB:SEQuence:STEP:VOLTage:UDEFined:DWELl? <
Specifies the dwell time for each user-defined current Arb point for Arb Sequence steps. The last value
in the sequence is the step number.
Range in seconds
All Models except N678xA
0 - 0.262144
0 - 2.62144
0 - 26.2144
0 - 262.144
0 - 262.144 (all except N678xA SMU)
0 - 268.435 (N678xA SMU only
*RST 1 point with a value of 0.001
Step 0 - 99, *RST 0
Program a current dwell list: ARB:CURR:UDEF:DWEL 0.1,0.2,0.3,0.4,0.5,(@1)
Program a voltage dwell list: ARB:VOLT:UDEF:DWEL 0.1,0.2,0.3,0.4,0.5,(@1)
Program a dwell list for step 0: ARB:SEQ:STEP:CURR:UDEF:DWEL 0.1,0.2,0.3,0.4,0.5, 0,(@1)
260
value
value
>{<,
value
value
>{<,
Dwell resolution
1 microsecond
10 microseconds
100 microseconds
1 millisecond
Parameter
Typical Return
<number of points>
(none)
>},(@<chanlist>)
>},(@<chanlist>)
value
value
step#
>{<,
>}, <
step#
>, (@<chanlist>)
value
value
step#
>{<,
>}, <
step#
>, (@<chanlist>)
Range in seconds
Dwell resolution
Models N678xA only
0 - 0.268435
1.024 microsecond
0 - 2.68435
10.24 microsecond
0 - 26.8435
102.4 microsecond
0 - 268.435
1.024 millisecond
Typical Return
<dwell time>
Keysight N6705C Operating and Service Guide
>, (@<chanlist>)
>, (@<chanlist>)
(none)