Table of Contents
Hard Disk Drive Specifications
1
Table of Contents
3
1 General
9
Introduction
9
Glossary
10
General Caution
10
2 Outline of the Drive
11
3 Fixed Disk Subsystem Description
13
Control Electronics
13
Head Disk Assembly
13
Actuator
13
4 Drive Characteristics
15
Formatted Capacity
15
Data Sheet
15
Inquiry Information
16
Product ID
16
World Wide ID - Block Assignment
16
Cylinder Allocation
17
Performance Characteristics
18
Command Overhead
18
Mechanical Positioning
19
Drive Ready Time
20
Spindle Stop Time
20
Data Transfer Speed
21
Buffering Operation (Read Ahead/Write Cache)
21
Throughput
22
5 Data Integrity
23
Equipment Status
23
Error Recovery Procedure
23
6 Physical Format
25
Shipped Format (P-List)
25
Reassigned Format (G-List)
25
7 Specification
27
Electrical Interface Specification
27
Power Connector
27
SCSI Bus Connector
28
SCSI Cable
31
SCSI Bus Terminator
31
Hot Plug/Unplug
31
SCSI Bus Electrical Characteristics
31
Auxiliary Connector on 68 Pin Model
32
Option Jumper Block
33
Jumper Signal Description on J6
34
Jumper Signal Description on
36
Environment
38
Corrosion Test
38
Cooling Requirements
39
DC Power Requirements
40
Input Voltage
40
Power Supply Current
40
Ripple Voltage
41
Power Consumption Efficiency Index
41
Reliability
42
Start/Stop Cycles
42
Data Reliability
42
Seek/ID Miscompare Errors
42
Equipment Errors
42
Failure Prediction (PFA/S.M.A.R.T.)
42
Preventive Maintenance
42
Temperature Warning
43
Mechanical Specifications
44
Outline
44
Mechanical Dimensions
45
Interface Connector
46
Mounting Positions and Tappings
47
Heads Unload and Actuator Lock
48
Breather Hole
48
Vibration and Shock
49
Operating Vibration
49
Non-Operating Vibrations
50
Operating Shock
50
Non-Operating Shock
51
Acoustics
52
Sound Power Levels
52
Identification Labels
53
Electromagnetic Compatibility
54
CE Mark
54
C-Tick Mark
54
Safety
55
UL and CSA Standard Conformity
55
IEC Compliance
55
German Safety Mark
55
Flammability
55
8 SCSI Command Set
57
SCSI Control Byte
58
Abbreviations
58
Byte Ordering Conventions
58
Format Unit (04)
59
Defect List
60
Defect Descriptor
61
Inquiry (12)
64
Inquiry Data
66
Log Select (4C)
74
Log Sense (4D)
75
Log
76
Log Sense
77
Log Sense
78
Log Sense
80
Log Sense
82
Log Sense
84
Log Sense
85
Log Sense
86
Log Sense
87
Log Sense
88
Log Sense Page 2F
91
Mode Sense (1A)
92
Mode Parameter List
93
Block Descriptor
95
Page Descriptor
96
Mode Page 0 (Vendor Unique Parameters)
97
Mode Page 1 (Read/Write Error Recovery Parameters)
100
Mode Page 2 (Disconnect/Reconnect Parameters)
105
Mode Page 3 (Format Device Parameters)
107
Mode Page 4 (Rigid Disk Drive Geometry Parameters)
109
Mode Page 7 (Verify Error Recovery Parameters)
110
Mode Page 8 (Caching Parameters)
112
Mode Page a (Control Mode
115
Mode Page 0C (Notch Parameters)
117
Mode Page 19 (Port Control)
119
Mode Page 1A (Power Control)
120
Mode Page 1C (Informational Exceptions Control)
121
Mode Sense (5A)
123
Mode Select (15)
124
Mode Select (55)
126
Persistent Reserve in (5E)
127
Service Action
127
Parameter Data for Read Keys
128
Parameter Data for Read Reservations
128
Persistent Reserve out (5F)
130
Service Action
131
Scope
134
Type
134
Parameter List
136
Summary
136
Pre-Fetch (34)
138
Read (08)
139
Read Buffer (3C)
140
Combined Header and Data (Mode 0000B)
141
Read Data (Mode 0010B)
141
Descriptor (Mode 0011B)
141
Read Data from Echo Buffer (Mode 1010B)
142
Echo Buffer Descriptor (Mode 1011B)
142
Read Capacity
143
Read Defect Data (37)
145
Defect List Header
146
Bytes from Index Format (100B)
146
Physical Sector Format (101B)
147
Read Defect Data (B7)
148
Defect List Header
149
Bytes from Index Format (100B)
149
Physical Sector Format (101B)
150
Read Extended
151
Read Long (3E)
152
Reassign Blocks (07)
153
Receive Diagnostics (1C)
155
Receive Diagnostic
155
Receive Diagnostic
156
Receive Diagnostic
157
Release (17)
158
Release (57)
159
Report Device Identifier (A3)
160
Report Lun (A0)
162
Request Sense (03)
163
Reserve
164
Reserve
165
Rezero Unit
166
Seek (0B)
167
Seek Extended (2B)
168
Send Diagnostic (1D)
169
Send Diagnostic
171
Send Diagnostic
172
Set Device Identifier (A4)
173
START/STOP Unit (1B)
175
Synchronize Cache (35)
176
Test Unit Ready (00)
177
Verify (2F)
178
Write (0A)
179
Write and Verify (2E)
180
Write Buffer (3B)
181
Combined Header and Data (Mode 0000B)
182
Write Data (Mode 0010B)
182
Download Microcode (Mode 0100B)
183
Download Microcode and Save (Mode 0101B)
183
Write Data to Echo Buffer (Mode 1010B)
184
Write Extended (2A)
185
Write Long (3F)
186
Write same (41)
187
9 SCSI Status Byte
189
10 SCSI Message System
191
Supported Messages
191
Command Complete (00)
192
Synchronous Data Transfer Request (01,03,01H)
192
Wide Data Transfer Request (01,02,03H)
197
Parallel Protocol Request (01,06,04H)
199
Save Data Pointer (02)
200
Restore Pointers (03)
200
Disconnect (04)
200
Initiator Detected Error (05)
200
Abort (06)
201
Message Reject (07)
201
No Operation (08)
201
Message Parity Error (09)
201
Linked Command Complete (0A)
202
Linked Command Complete with Flag (0B)
202
Bus Device Reset (0C)
202
Abort Tag (0D)
202
Clear Queue Tag (0E)
202
QUEUE TAG MESSAGES (20H, 21H, 22H)
203
IGNORE WIDE RESIDUE (23H)
204
Identify (80 - Ff)
204
Supported Message Functions
205
Attention Condition
206
SCSI Bus Related Error Handling Protocol
207
Unexpected BUS FREE Phase Error Condition
207
MESSAGE out Phase Parity Error
207
MESSAGE in Phase Parity Error (Message Parity Error)
207
COMMAND Phase Parity Error
207
DATA out Phase Parity Error
207
INITIATOR DETECTED ERROR Message
208
MESSAGE REJECT Message
208
11 Additional Information
209
SCSI Protocol
209
Priority of SCSI Status Byte Reporting
209
Invalid LUN in Identify Message
210
Incorrect Initiator Connection
210
Command Processing During Execution of Active I/O Process
211
Unit Attention Condition
213
Command Processing During Startup and Format Operations
214
Internal Error Condition
214
Deferred Error
215
Degraded Mode
215
Command Processing While Reserved
221
Priority Commands
222
Command Queuing
222
Queue Depth
223
Tagged Queuing
223
Untagged Queuing
223
Command Queuing Rule
223
Queue Full Status
223
Device Behavior on Command Queuing
223
Command Reordering
224
Concurrent I/O Process
224
Back to Back Write
224
Write Cache
225
Automatic Rewrite/Reallocate
225
Segmented Caching
227
Overview
227
Read Ahead
227
Reselection Timeout
227
Single Initiator Selection
227
Non-Arbitrating Systems
227
Selection Without ATN
228
Multiple Initiator Environment
228
Initiator Sense Data
228
Initiator Mode Select/Mode Sense Parameters
228
Initiator Data Transfer Mode Parameter
228
Contingent Allegiance Condition
228
Reset
229
Reset Sources
229
Reset Actions
229
Diagnostics
230
Power on Diagnostics
230
Diagnostics Command
230
Diagnostics Fault Reporting
230
Idle Time Function
231
12 SCSI Sense Data
233
SCSI Sense Data Format
233
Sense Data Description
234
Valid (Bit 7 of Byte 0)
234
Error Code (Bit 6 - 0 of Byte 0)
234
ILI: Incorrect Length Indicator (Bit 5 of Byte 2)
234
Sense Key (Bit 3 - 0 of Byte 2)
234
Information Bytes (Byte 3 through 6)
235
Additional Sense Length (Byte 7)
235
Command Specific Information (Byte 8 through 11)
235
Additional Sense Code/Qualifier (Byte 12 and 13)
236
FRU : Field Replaceable Unit (Byte 14)
240
Sense Key Specific (Byte 15 through 17)
240
Reserved (Byte 18 through 19)
242
Vendor Unique Error Information (Byte 20 through 23)
242
Physical Error Record (Byte 24 Thru 29)
247
Reserved (Byte 30 through 31)
247
Advertisement
IBM Ultrastar 36LZX Installation And Reference Manual (26 pages)
3.5 inch Ultra 160 SCSI hard disk drive
Brand:
IBM
| Category:
Storage
| Size: 0.29 MB
Table of Contents
Technical Support
2
Table of Contents
4
Introduction
5
Getting Started
6
Handling Precautions
6
Tools for Installation
6
Begin the Hardware Install
6
Configure the Jumper Settings
7
Option Jumper Blocks
7
Assign a SCSI Address
8
Enable Optional Features
8
The Auxiliary Connector on 68 Pin Models
10
Mount the Drive
11
Attach the Cables
12
Drives with 68 Pin Connectors
12
Drives with 80 Pin Connectors
12
Complete the Hardware Install
12
Verify Host Adapter Settings
13
Partition the Drive
16
Format the Drive
18
Install the Operating System
18
Appendix
19
How to Create a Bootable Diskette
19
Controller Information
19
Compatibility
20
DDYS Models
20
DPSS Models
21
Troubleshooting
22
Glossary
24
IBM Ultrastar 36LZX Quick Installation Manual (2 pages)
Ultra 160 SCSI
Brand:
IBM
| Category:
Storage
| Size: 0.13 MB
Advertisement
Advertisement
Related Products
IBM Ultrastar 36ZX
IBM Ultrastar 36LP
IBM Ultrastar 36XP
IBM Ultrastar 36XP DRHS-36V
IBM Ultrastar 36XP DRHS-36D
IBM TotalStorage Ultrium 3580 L23
IBM 342 7208
IBM Ultrium 3580
IBM 3401-S00
IBM 3453-F7E
IBM Categories
Server
Desktop
Storage
Laptop
Monitor
More IBM Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL