Technical Data; Technical Data 230V (Size 13 To 21) - KEB COMBIVERT F5 Instruction Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

2. Technical Data
2.1 Technical data 230V (size 13 to 21)
Inverter Size
Recommended Motor Power
Housing size
Input Ratings
Supply voltage frequency [Hz]
Rated input current [A]
Recommended wire gauge
Output Ratings
Rated output power [kVA] .5
Rated motor power [kW] 5.5
Rated output current [A]
Peak current (30 seconds)
Over current fault (E.OC) trip level [A]
Output frequency [Hz]
Rated switching frequency
Maximum switching frequency [kHz] 16
Power loss at rated operation
Stall current at 4kHz [A]
Stall current at 8kHz [A]
Stall current at 16kHz [A] 16.8 16.8 33
Braking Circuit
Min. braking resistance[Ohm] 16
Typ. braking resistance[Ohm] 27
Max. braking current [A]
Installation Information
Max. shielded motor cable length
Tightening torque for power terminals [in lb] 11
Environmental
Max. heat sink temperature TOH [°C]
Storage temperature [°C]
Operating temperature [°C]
Housing design / protection
Relative humidity
Approvals
Tested in accordance with...
Standards for emitted interference
Standards for noise immunity
Climatic category
i
The recommended motor rating is for 4/6 pole standard motors. When using motors with different
numbers of poles, the inverter must be dimensioned based on the motor rated current. Contact the
manufacturer for special frequency motors.
The power rating of the inverter must be de-rated for operation above 3,300 ft (1000 m). Reduce the
rated power 1% for each additional 330 ft (100 m). The maximum elevation for operation is 6,560 ft
(2000 m)
18
13
14
[hp] 7.5
10
E
E
Supply voltage [V]
Input phases
3
3
28
36
[awg] 10
8
1)
13
7.5
22
28
[A]
36
4.5
2)
43
5
Output voltage [V]
Generally 0 to 1600Hz (limited by control board and carrier frequency)
[kHz]
8
4
3)
16 16
[W] 20 350 330
4)
24
33 33
24
24 33
16 8.0
20 20
25
25 50
[ft] 330 330
5)
11
15
16
15
20
G
G
H
H
180...260 ±0 (230 V rated voltage)
50 / 60 +/- 2
3
3
55
63
8
6
4
17
23
11
15
42
57
72
86

86
104
118
3 x 0...V input (3 x 0...255V
16
4
16
16
8
16
16
330
430
550
36
53
73
31
53
73
26
53
66
8.0
5.6
5.6
13
13
10
50
70
70
330
11
35
0°C / 14°F
-25...70 °C / -13...158°F
-10...45 °C / 14...113°F
Chassis / IP20 / Pollution Degree 2
max. 5% without condensation
EN 61800-3 /UL508C
EN 55011 Class B / EN 55022 Class A
IEC 1000-4-2 / -3 / -4 / -5/ -6
3K3 in accordance with EN 50178
17
25
H
3
2
3
2
18.5
84
118
151
168
142
181
201
)
2)
16
4
4
16
16
16
550
850
850
73
126
118
73
10
7
73
2
5
4.7
7.0
85
330
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents