9.0 Input/Output Configuration
9.1 Digital Input Parameters
di. 0
Determines whether the inputs are PNP (sourcing) or NPN (sinking). This setting
is applied globaly to all inputs.
Input Type
di. 3
This parameter controls a digital noise filter which can be used to mask relay bounce
or other unwanted momentary signals. This filter applies to all digital inputs except
Noise Filter
the enable input at X2A.16. The enable input is processed immediately
140
The digital input parameters can be used to configure the digital
inputs for operation. Normally these parameters only need to be
adjusted by the Elevator control builder.
Unit: -
Value Range: PnP, nPn
Factory Setting: PnP
Unit: mSec
Value Range: 0 ... 127 mSec
Factory Setting: 5 mSec