Technical Data; Operating Conditions - KEB COMBIVERT F5 Series Instruction Manual

Hide thumbs Also See for COMBIVERT F5 Series:
Table of Contents

Advertisement

Technical Data

2.
Technical Data
2.1

Operating conditions

Definition acc.
Site altitude
Ambient conditions during operation
Temperature
Climate
Mechanical
Contamination
Ambient conditions during transport
Temperature
Climate
Mechanical
Contamination
Ambient conditions for the storage
Temperature
Climate
Mechanical
Contamination
Type of protection
Environment
Definition acc.
EMC emitted interference
Cable-based interferences
Radiated interferences
Interference immunity
Static discharges EN 61000-4-2
Burst - control lines + bus EN 61000-4-4
Burst - mains supply EN 61000-4-4
Surge - mains supply EN 61000-4-5
Electromagnetic fields EN 61000-4-3
Cable-fed disturbances, induced
by high frequency fields
Voltage variation /
voltage drop
Voltage unsymmetries /
Frequency changes
1)
This product can cause high frequency disturbances in residential areas (category C1)
which require noise suppression measures.
The specified value is only meet in connection with a corresponding filter.
2)
GB - 12
Standard
EN 61800-2
EN 61800-5-1
Humidity
EN 60721-3-3
Vibration
Gas
Solids
Humidity
Vibration
EN 60721-3-2
Surge
Gas
Solids
Humidity
Vibration
EN 60721-3-1
Surge
Gas
Solids
EN 60529
IEC 664-1
EN 61800-3
EN 61000-4-6
EN 61000-2-1
EN 61000-2-4
Standard/
class
Inverter product standard: rated specifications
Inverter product standard: general safety
With site altitudes over 1000 m a derating of 1 % per
100 m must be taken into consideration.
extended to -10...45 °C (use frost protection for water
3K3
cooling systems and temperatures below zero)
3K3
3M1
3C2
3S2
2K3
2K3
2M1
2M1
2C2
2S2
1K4
1K3
1M1
1M1
1C2
1S2
IP20
Earlier limit value A (B optional) according to EN55011
C2
1)2)
C2
Earlier limit value according to EN55011
2)
8 kV
AD (air discharge) and CD (contact discharge)
2 kV
4 kV
1 / 2 kV
10 V/m
10 V
3
3
Instructions
max. 2000 m above sea level
5...85 % (without condensation)
Drain heat sink completely
(without condensation)
max. 100 m/s²; 11 ms
Drain heat sink completely
(without condensation)
max. 100 m/s²; 11 ms
Pollution degree 2
Inverter product standard: EMC
Phase-phase / phase-ground
0.15-80 MHz
MM
+10 % -15 %
90 %
3 %
2 %