Diagnostic parameters
ru.20
This is the actual phase to phase output voltage to the motor.
Output voltage
Units: Volts
ru.21
The raw status of the input terminals. Each input is binary weighted according to the
table below. If an input is activated the value corresponding to the input is displayed.
Input terminal
If multiple inputs are activated the sum of the values is displayed. This parameter
state
includes software linked inputs.
Input Terminal
X2A.16
X2A.17
X2A.14
X2A.15
X2A.10
X2A.11
X2A.12
X2A.13
none
none
none
none
ru.22
This is the processed status, after filters, software switches etc. of the inputs. The
same weighting scheme applied as in parameter ru.21.
Input terminal
state
ru.23
This is the state of the internal output conditions. Multiple active conditions results
in the sum of the values.
Output terminal
state
126
Function
Enable
Reset
Up
Down
Option-Emerg. Pwr. 16
Leveling speed
High Level speed
High Speed
Internal function
Internal function
Internal function
Internal function
Condition
Value
0
1
1
2
2
4
3
8
4
16
5
32
6
64
7
128
Example: Input X2A.16 and
Value
X2A.14 are active.
1
2
1 + 4 = 5
4
8
Other examples:
6 = Inspection speed
32
160 = Intermediate speed 1
64
12 = intermediate speed 2
128
224 = intermediate speed 3
256
+ 5 for up
512
+ for down
1024
2048

Hide quick links:

Advertisement

Table of Contents
loading